跳到主要导航 跳到搜索 跳到主要内容

What is needed to make low-density lipoprotein transport in human aorta computational models suitable to explore links to atherosclerosis? Impact of initial and inflow boundary conditions

  • Giuseppe De Nisco
  • , Peng Zhang
  • , Karol Calò
  • , Xiao Liu
  • , Raffaele Ponzini
  • , Cristina Bignardi
  • , Giovanna Rizzo
  • , Xiaoyan Deng
  • , Diego Gallo
  • , Umberto Morbiducci*
  • *此作品的通讯作者
  • Polytechnic University of Turin
  • Beihang University
  • Cineca Consortium of Universities
  • National Research Council of Italy

科研成果: 期刊稿件文章同行评审

摘要

Personalized computational hemodynamics (CH) is a promising tool to clarify/predict the link between low density lipoproteins (LDL) transport in aorta, disturbed shear and atherogenesis. However, CH uses simplifying assumptions that represent sources of uncertainty. In particular, modelling blood-side to wall LDL transfer is challenged by the cumbersomeness of protocols needed to obtain reliable LDL concentration profile estimations. This paucity of data is limiting the establishment of rigorous CH protocols able to balance the trade-offs among the variety of in vivo data to be acquired, and the accuracy required by biological/clinical applications. In this study, we analyze the impact of LDL concentration initialization (initial conditions, ICs) and inflow boundary conditions (BCs) on CH models of LDL blood-to-wall transfer in aorta. Technically, in an image-based model of human aorta, two different inflow BCs are generated imposing subject-specific inflow 3D PC-MRI measured or idealized (flat) velocity profiles. For each simulated BC, four different ICs for LDL concentration are applied, imposing as IC the LDL distribution resulting from steady-state simulations with average conditions, or constant LDL concentration values. Based on CH results, we conclude that: (1) the imposition of realistic 3D velocity profiles as inflow BC reduces the uncertainty affecting the representation of LDL transfer; (2) different LDL concentration ICs lead to markedly different patterns of LDL transfer. Given that it is not possible to verify in vivo the proper LDL concentration initialization to be applied, we suggest to carefully set and unambiguously declare the imposed BCs and LDL concentration IC when modelling LDL transfer in aorta, in order to obtain reproducible and ultimately comparable results among different laboratories.

源语言英语
页(从-至)33-42
页数10
期刊Journal of Biomechanics
68
DOI
出版状态已出版 - 8 2月 2018

学术指纹

探究 'What is needed to make low-density lipoprotein transport in human aorta computational models suitable to explore links to atherosclerosis? Impact of initial and inflow boundary conditions' 的科研主题。它们共同构成独一无二的学术指纹。

引用此