TY - JOUR
T1 - Unveiling time-varying signals of ultralight bosonic dark matter at collider and beam dump experiments
AU - Guo, Jinhui
AU - He, Yuxuan
AU - Liu, Jia
AU - Wang, Xiao Ping
AU - Xie, Ke Pan
N1 - Publisher Copyright:
© 2023, Springer Nature Limited.
PY - 2023/12
Y1 - 2023/12
N2 - The ultralight boson represents a promising dark matter candidate exhibiting unique wave-like behaviors. These properties could transfer to the dark mediator, such as the kinetic mixing dark photon, which can be a link between the dark and Standard Model sectors, resulting in periodic oscillations of its mass. We propose a method to detect ultralight dark matter using dark mediators in collider and beam dump experiments, distinguishing it from conventional atomic, molecular, and optical methods. The time-varying nature of dark mediator mass exhibits a double-peak spectrum, reducing traditional constraints by 1 to 2 orders of magnitude, due to decreased luminosity exposure in each resonant mass bin. To enhance sensitivity, we utilize event time-stamps in the CMS Open Data and demonstrate that this technique boosts sensitivity by approximately one order of magnitude compared to the time-blind method. Moreover, it proves effective in detecting the invisible decay of the dark mediator.
AB - The ultralight boson represents a promising dark matter candidate exhibiting unique wave-like behaviors. These properties could transfer to the dark mediator, such as the kinetic mixing dark photon, which can be a link between the dark and Standard Model sectors, resulting in periodic oscillations of its mass. We propose a method to detect ultralight dark matter using dark mediators in collider and beam dump experiments, distinguishing it from conventional atomic, molecular, and optical methods. The time-varying nature of dark mediator mass exhibits a double-peak spectrum, reducing traditional constraints by 1 to 2 orders of magnitude, due to decreased luminosity exposure in each resonant mass bin. To enhance sensitivity, we utilize event time-stamps in the CMS Open Data and demonstrate that this technique boosts sensitivity by approximately one order of magnitude compared to the time-blind method. Moreover, it proves effective in detecting the invisible decay of the dark mediator.
UR - https://www.scopus.com/pages/publications/85168653515
U2 - 10.1038/s42005-023-01350-6
DO - 10.1038/s42005-023-01350-6
M3 - 文章
AN - SCOPUS:85168653515
SN - 2399-3650
VL - 6
JO - Communications Physics
JF - Communications Physics
IS - 1
M1 - 225
ER -