TY - JOUR
T1 - Ultrasound channel attention residual network for medical plane wave echo data-based average sound speed estimation
AU - Zheng, Fangyuan
AU - Fan, Shangchun
AU - Wei, Yihang
AU - Wang, Zihao
AU - Wei, Xiaorui
AU - Borjigin, Wonbayar
AU - Jiang, Jue
AU - Qu, Xiaolei
N1 - Publisher Copyright:
© 2024
PY - 2024/5/31
Y1 - 2024/5/31
N2 - The average sound speed estimation is crucial for ultrasound imaging quality and diagnostic. In this article, the deep learning techniques were utilized and an innovative Ultrasound Channel Attention Residual Network (UCA-ResNet) was proposed. The UCA-ResNet incorporated a specially designed Ultrasound Channel Attention (UCA) block, which effectively enhanced relevant ultrasound channel features and convolutional channel features. For evaluation, the simulation, phantom, and in vivo experiments were conducted. In the simulation experiment, UCA-ResNet achieved remarkable results, with a mean absolute error (MAE) of 0.40 m/s, root mean square error (RMSE) of 1.25 m/s, standard deviation of error (SDE) of 1.25 m/s, and a one-time estimation time of 3.67 ms. Moreover, the phantom and in vivo experiments further validated the high accuracy and low computational cost of UCA-ResNet. The UCA-ResNet can accurately estimate the average sound speed using a single plane wave echo data while maintaining low computational cost. It has potential in enhancing medical ultrasound imaging quality and providing novel diagnostic insights. (Code and data will be available upon acceptance of the manuscript.)
AB - The average sound speed estimation is crucial for ultrasound imaging quality and diagnostic. In this article, the deep learning techniques were utilized and an innovative Ultrasound Channel Attention Residual Network (UCA-ResNet) was proposed. The UCA-ResNet incorporated a specially designed Ultrasound Channel Attention (UCA) block, which effectively enhanced relevant ultrasound channel features and convolutional channel features. For evaluation, the simulation, phantom, and in vivo experiments were conducted. In the simulation experiment, UCA-ResNet achieved remarkable results, with a mean absolute error (MAE) of 0.40 m/s, root mean square error (RMSE) of 1.25 m/s, standard deviation of error (SDE) of 1.25 m/s, and a one-time estimation time of 3.67 ms. Moreover, the phantom and in vivo experiments further validated the high accuracy and low computational cost of UCA-ResNet. The UCA-ResNet can accurately estimate the average sound speed using a single plane wave echo data while maintaining low computational cost. It has potential in enhancing medical ultrasound imaging quality and providing novel diagnostic insights. (Code and data will be available upon acceptance of the manuscript.)
KW - Average sound speed estimation
KW - Deep learning
KW - Medical ultrasound imaging
KW - Phase aberration
KW - Ultrasound channel attention
UR - https://www.scopus.com/pages/publications/85189702816
U2 - 10.1016/j.measurement.2024.114634
DO - 10.1016/j.measurement.2024.114634
M3 - 文章
AN - SCOPUS:85189702816
SN - 0263-2241
VL - 231
JO - Measurement: Journal of the International Measurement Confederation
JF - Measurement: Journal of the International Measurement Confederation
M1 - 114634
ER -