TY - JOUR
T1 - Two-dimensional monte carlo filter for a non-gaussian environment
AU - Qiang, Xingzi
AU - Xue, Rui
AU - Zhu, Yanbo
N1 - Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021/6/2
Y1 - 2021/6/2
N2 - In a non-Gaussian environment, the accuracy of a Kalman filter might be reduced. In this paper, a two-dimensional Monte Carlo Filter is proposed to overcome the challenge of the non-Gaussian environment for filtering. The two-dimensional Monte Carlo (TMC) method is first proposed to improve the efficacy of the sampling. Then, the TMC filter (TMCF) algorithm is proposed to solve the non-Gaussian filter problem based on the TMC. In the TMCF, particles are deployed in the confidence interval uniformly in terms of the sampling interval, and their weights are calculated based on Bayesian inference. Then, the posterior distribution is described more accurately with less particles and their weights. Different from the PF, the TMCF completes the transfer of the distribution using a series of calculations of weights and uses particles to occupy the state space in the confidence interval. Numerical simulations demonstrated that, the accuracy of the TMCF approximates the Kalman filter (KF) (the error is about 10−6) in a two-dimensional linear/ Gaussian environment. In a two-dimensional linear/non-Gaussian system, the accuracy of the TMCF is improved by 0.01, and the computation time reduced to 0.067 s from 0.20 s, compared with the particle filter.
AB - In a non-Gaussian environment, the accuracy of a Kalman filter might be reduced. In this paper, a two-dimensional Monte Carlo Filter is proposed to overcome the challenge of the non-Gaussian environment for filtering. The two-dimensional Monte Carlo (TMC) method is first proposed to improve the efficacy of the sampling. Then, the TMC filter (TMCF) algorithm is proposed to solve the non-Gaussian filter problem based on the TMC. In the TMCF, particles are deployed in the confidence interval uniformly in terms of the sampling interval, and their weights are calculated based on Bayesian inference. Then, the posterior distribution is described more accurately with less particles and their weights. Different from the PF, the TMCF completes the transfer of the distribution using a series of calculations of weights and uses particles to occupy the state space in the confidence interval. Numerical simulations demonstrated that, the accuracy of the TMCF approximates the Kalman filter (KF) (the error is about 10−6) in a two-dimensional linear/ Gaussian environment. In a two-dimensional linear/non-Gaussian system, the accuracy of the TMCF is improved by 0.01, and the computation time reduced to 0.067 s from 0.20 s, compared with the particle filter.
KW - Non-gaussian environment
KW - Nonlinear filter
KW - Particle filter
KW - Sequence monte carlo
UR - https://www.scopus.com/pages/publications/85107420115
U2 - 10.3390/electronics10121385
DO - 10.3390/electronics10121385
M3 - 文章
AN - SCOPUS:85107420115
SN - 2079-9292
VL - 10
JO - Electronics (Switzerland)
JF - Electronics (Switzerland)
IS - 12
M1 - 1385
ER -