跳到主要导航 跳到搜索 跳到主要内容

Two-detector arbitrary Nth-order HBT-type ghost diffraction

科研成果: 期刊稿件文章同行评审

摘要

The imaging quality using two-detector arbitrary Nth-order intensity correlation in optics is investigated. It is theoretically demonstrated that with the order of intensity correlation N increases, the visibility of the retrieved image enhances promptly; and different n-fold intensity on one arm of the intensity correlation leads to different visibility, whereas the resolution is independent of N and n. The numerical simulation results are shown to be consistent with our theoretical analysis results. Furthermore, a particular imaging system of the two-detector Nth-order Hanbury - Brown - Twiss (HBT) type ghost diffraction is conceived by using a slit as the object, the image quality by this type of ghost diffraction is investigated. The experimental results coincide with our theoretical analysis.

源语言英语
文章编号014205
期刊Chinese Physics Letters
29
1
DOI
出版状态已出版 - 1月 2012

指纹

探究 'Two-detector arbitrary Nth-order HBT-type ghost diffraction' 的科研主题。它们共同构成独一无二的指纹。

引用此