Transrenal deployment of a modular stent graft to repair AAAs with short necks: Experiments in dogs

  • Robert Guidoin*
  • , Miguel A.M. Peirano
  • , Hector D. Barone
  • , Yvan Douville
  • , Ze Zhang
  • , Randolph Guzman
  • , Hernan Bertoni
  • , Yahye Merhi
  • , Georgi R. Marinov
  • , Robert McGregor
  • , Hongbo Zhang
  • , Daniel Chappard
  • , Guy Dionne
  • , Xiaoyan Deng
  • *此作品的通讯作者
  • Université Laval
  • Hospital General de Agudos José María Ramos Mejía
  • Latecba SA
  • CHUQ
  • St. Boniface General Hospital
  • Universidad de Buenos Aires
  • University of Montreal
  • Medical University of Varna
  • Université d'Angers

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

Severely angulated (> 60°) or short (< 15mm) proximal necks remain significant anatomical limitations for endovascular stent-graft repairs for abdominal aortic aneurysms. Ensuring proper proximal fixation of the stent-graft to the host artery without the short-or long-term risks of endoleak or migration represents a particular technical challenge for these anatomical circumstances. An innovative balloon expandable stent combined with a weft-knitted prosthesis was specifically designed for these situations by modelling the stent to the neck anatomy without overdistension or potential barotrauma allowing better incorporation of the device. The Latecba stent-graft consists of a 2 parts modular design. The first one, Module A, is deployed at the transrenal level and consists of a Palmaz type stent whose first half is bare and second half is sutured to a crimped weft-knitted polyester graft whose distal end holds a constriction. The second Module B is a non-crimped weft-knitted graft attached to 2 stainless steel stents. The first stent is entirely contained in the proximal textile tube, allowing fixation to module A. The second stent, which is left uncovered over the distal third, ensures proper fixation of the stent-graft distally. Following the creation of a prosthetic aneurysm in the infrarenal aorta in 32 dogs, 29 received the Latecba stent-graft for scheduled durations of 10 days, 1 month, 3 months and 6 months. Proper deployment of the stent-grafts was achieved without difficulty. All 29 animals survived and the devices were all patent at sacrifice. No device defects or migrations were observed and the stent-grafts proved to be efficient in this setting to exclude the aneurysm. Analyses of the explanted devices (gross observations, RX, CT scan, IVUS, angioscopy) confirmed the stability of this modular stent-graft. Further on-going clinical investigations are warranted to validate this concept before this stent-graft becomes commercially available without any restriction.

源语言英语
页(从-至)310-339
页数30
期刊Artificial Cells, Blood Substitutes, and Immobilization Biotechnology
卷36
期4
DOI
出版状态已出版 - 8月 2008
已对外发布是

学术指纹

探究 'Transrenal deployment of a modular stent graft to repair AAAs with short necks: Experiments in dogs' 的科研主题。它们共同构成独一无二的学术指纹。

引用此