The micro-solution electrochemical method to evaluate rebar corrosion in reinforced concrete structures

  • Yuwan Tian
  • , Chaofang Dong*
  • , Xuequn Cheng
  • , Yingqi Wan
  • , Gui Wang
  • , Kui Xiao
  • , Xiaogang Li
  • *此作品的通讯作者
  • University of Science and Technology Beijing
  • Guangdong Ocean University

科研成果: 期刊稿件文章同行评审

摘要

An electrochemical method by submersing the HRB400 rebar specimen in simulated micro pore solution (47.125 μL) is proposed to rapidly evaluate the corrosion rate of HRB400 in concrete. The results show that the corrosion rate of HRB400 in micro-solution is about five times lower than that in bulk solution. The reason for this difference is the anodic polarization caused by the higher concentration of dissolved iron ions in micro-solution. There is a small relational dispersed degree of corrosion rate measured by the optimized electrochemical cell in micro-solution and the real site studies.

源语言英语
页(从-至)607-614
页数8
期刊Construction and Building Materials
151
DOI
出版状态已出版 - 1 10月 2017