跳到主要导航 跳到搜索 跳到主要内容

The identification of sub-centimetre nodules by near-infrared fluorescence thoracoscopic systems in pulmonary resection surgeries

  • Yamin Mao
  • , Chongwei Chi
  • , Fan Yang
  • , Jian Zhou
  • , Kunshan He
  • , Hao Li
  • , Xiuyuan Chen
  • , Jinzuo Ye
  • , Jun Wang
  • , Jie Tian*
  • *此作品的通讯作者
  • CAS - Institute of Automation
  • University of Chinese Academy of Sciences
  • Chinese Academy of Sciences
  • Peking University

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

OBJECTIVES: Current surgical procedures lack high-sensitivity intraoperative imaging guidance, leading to undetected micro tumours. In vivo near-infrared (NIR) fluorescence imaging provides a powerful tool for identifying small nodules. The aim of this study was to examine our experience of using 2 different NIR devices in pulmonary resection surgery. METHODS: From August 2015 to October 2016, 36 patients with lung nodules underwent NIR fluorescence imaging thoracoscopic surgery. Two NIR devices: a D-Light P system and a SUPEREYE system were used. Patients were administered an injection of indocyanine green (ICG) through the peripheral vein 24 h preoperatively. During surgery, traditional white-light thoracoscopic exploration was performed first, followed by ICG-fluorescent-guided exploration. All detected nodules were resected and examined by a pathologist. RESULTS: Of the 36 patients, 76 nodules were resected. ICG-fluorescent imaging identified 68 nodules during in vivo exploration. The mean signal-to-background ratio of lung nodules in NIR exploration was 3.29 ± 1.81. The application of NIR devices led to the detection of 9 additional nodules that were missed using traditional detection methods (1mm computed tomography scan and white-light thoracoscopic exploration) in 7 patients (19.4%). Four of the 9 nodules were confirmed as malignant or atypical adenomatous hyperplasia (44.4%). The other 5 nodules were confirmed as false-positive nodules. The sensitivities and positive predictive values of the ICG-fluorescent imaging for lung tumours were 88.7% and 92.6%, respectively. CONCLUSIONS: This study demonstrated the feasibility and safety of using ICG-fluorescent imaging for multiple lung nodules identification in video-assisted thoracoscopic surgery pulmonary resection.

源语言英语
页(从-至)1190-1196
页数7
期刊European Journal of Cardio-thoracic Surgery
卷52
期6
DOI
出版状态已出版 - 12月 2017
已对外发布是

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 3 - 良好健康与福祉
    可持续发展目标 3 良好健康与福祉

学术指纹

探究 'The identification of sub-centimetre nodules by near-infrared fluorescence thoracoscopic systems in pulmonary resection surgeries' 的科研主题。它们共同构成独一无二的学术指纹。

引用此