T1 - The Bony Resection Accuracy with Patient-Specific Instruments during Total Knee Arthroplasty
T2 - A Retrospective Case Series Study
AU - Yuan, Liang
AU - Yang, Bin
AU - Wang, Xiaohua
AU - Sun, Bin
AU - Zhang, Ke
AU - Yan, Yichen
AU - Liu, Jie
AU - Yao, Jie
N1 - Publisher Copyright:
© 2021 Liang Yuan et al.
PY - 2021
Y1 - 2021
N2 - Purpose. Bony resection is the primary step during total knee arthroplasty. The accuracy of bony resection was highly addressed because it was deemed to have a good relationship with mechanical line. Patient-specific instruments (PSI) were invented to copy the bony resection references from the preoperative surgical plan during a total knee arthroplasty (TKA); however, the accuracy still remains controversial. This study was aimed at finding out the accuracy of the bony resection during PSI-assisted TKA. Methods. Forty-two PSI-assisted TKAs (based on full-length leg CT images) were analyzed retrospectively. Resected bones of every patient were given a CT scan, and three-dimensional radiographs were reconstructed. The thickness of each bony resection was measured with the three-dimensional radiographs and recorded. The saw blade thickness (1.27 mm) was added to the measurements, and the results represented intraoperative bone resection thickness. A comparison between intraoperative bone resection thickness and preoperatively planned thickness was conducted. The differences were calculated, and the outliers were defined as >3 mm. Results. The distal femoral condyle had the most accurate bone cuts with the smallest difference (median, 1.0 mm at the distal medial femoral condyle and 0.8 mm at the distal lateral femoral condyle) and the least outliers (none at the distal medial femoral condyle and 1 (2.4%) at the distal lateral femoral condyle). The tibial plateau came in second (median difference, 0.8 mm at the medial tibial plateau and 1.4 mm at the lateral tibial plateau; outliers, none at the medial tibial plateau and 1 (2.6%) at the lateral tibial plateau). Regardless of whether the threshold was set to >2 mm (14 (17.9%) at the tibial plateau vs. 12 (14.6%) at the distal femoral condyle, p>0.05) or >3 mm (1 (1.3%) at the tibial plateau vs. 1 (1.2%) at the distal femoral condyle, p>0.05), the accuracy of tibial plateau osteotomy was similar to that of the distal femoral condyle. Osteotomy accuracy at the posterior femoral condyle and the anterior femoral condyle were the worst. Outliers were up to 6 (15.0%) at the posterior medial femoral condyle, 5 (12.2%) at the posterior lateral femoral condyle, and 6 (15.8%) at the anterior femoral condyle. The percentages of overcut and undercut tended to 50% in most parts except the lateral tibial plateau. At the lateral tibial plateau, the undercut percentage was twice that of the overcut. Conclusion. The tibial plateau and the distal femoral condyle share a similar accuracy of osteotomy with PSI. PSI have a generally good accuracy during the femur and tibia bone resection in TKA. PSI could be a kind of user-friendly tool which can simplify TKA with good accuracy. Level of Evidence. This is a Level IV case series with no comparison group.
AB - Purpose. Bony resection is the primary step during total knee arthroplasty. The accuracy of bony resection was highly addressed because it was deemed to have a good relationship with mechanical line. Patient-specific instruments (PSI) were invented to copy the bony resection references from the preoperative surgical plan during a total knee arthroplasty (TKA); however, the accuracy still remains controversial. This study was aimed at finding out the accuracy of the bony resection during PSI-assisted TKA. Methods. Forty-two PSI-assisted TKAs (based on full-length leg CT images) were analyzed retrospectively. Resected bones of every patient were given a CT scan, and three-dimensional radiographs were reconstructed. The thickness of each bony resection was measured with the three-dimensional radiographs and recorded. The saw blade thickness (1.27 mm) was added to the measurements, and the results represented intraoperative bone resection thickness. A comparison between intraoperative bone resection thickness and preoperatively planned thickness was conducted. The differences were calculated, and the outliers were defined as >3 mm. Results. The distal femoral condyle had the most accurate bone cuts with the smallest difference (median, 1.0 mm at the distal medial femoral condyle and 0.8 mm at the distal lateral femoral condyle) and the least outliers (none at the distal medial femoral condyle and 1 (2.4%) at the distal lateral femoral condyle). The tibial plateau came in second (median difference, 0.8 mm at the medial tibial plateau and 1.4 mm at the lateral tibial plateau; outliers, none at the medial tibial plateau and 1 (2.6%) at the lateral tibial plateau). Regardless of whether the threshold was set to >2 mm (14 (17.9%) at the tibial plateau vs. 12 (14.6%) at the distal femoral condyle, p>0.05) or >3 mm (1 (1.3%) at the tibial plateau vs. 1 (1.2%) at the distal femoral condyle, p>0.05), the accuracy of tibial plateau osteotomy was similar to that of the distal femoral condyle. Osteotomy accuracy at the posterior femoral condyle and the anterior femoral condyle were the worst. Outliers were up to 6 (15.0%) at the posterior medial femoral condyle, 5 (12.2%) at the posterior lateral femoral condyle, and 6 (15.8%) at the anterior femoral condyle. The percentages of overcut and undercut tended to 50% in most parts except the lateral tibial plateau. At the lateral tibial plateau, the undercut percentage was twice that of the overcut. Conclusion. The tibial plateau and the distal femoral condyle share a similar accuracy of osteotomy with PSI. PSI have a generally good accuracy during the femur and tibia bone resection in TKA. PSI could be a kind of user-friendly tool which can simplify TKA with good accuracy. Level of Evidence. This is a Level IV case series with no comparison group.
UR - https://www.scopus.com/pages/publications/85102086151
U2 - 10.1155/2021/8674847
DO - 10.1155/2021/8674847
M3 - 文章
C2 - 33644230
AN - SCOPUS:85102086151
SN - 2314-6133
VL - 2021
JO - BioMed Research International
JF - BioMed Research International
M1 - 8674847
ER -