TY - JOUR
T1 - TDLAS Tomography System for Online Imaging and Dynamic Process Playback of Temperature and Gas Mole Fraction
AU - Li, Mingxiang
AU - Xu, Lijun
AU - Cao, Zhang
N1 - Publisher Copyright:
© 1963-2012 IEEE.
PY - 2022
Y1 - 2022
N2 - Tunable diode laser absorption spectroscopy (TDLAS) tomography enables online diagnosis of dynamic flames by imaging its temperature variations and exhaust gases, owing to its rapid response. Each tomographic image requires huge laser absorption spectrum data along multiple laser paths. For a high temporal resolution, the data sampling rate needs to be as high as possible which challenges the hardware implementation of parallel data acquisition (DAQ) of multiple channels. An online TDLAS tomography system was designed on field programmable gate array (FPGA) and PC for temperature and gas mole fraction distribution measurement. An on-chip parameter extraction module based on digital lock-in amplifier (DLIA) extracts absorption spectrum parameters at 1000 frames/s (FPS), and the framerate of real-time reconstruction on the host PC can reach up to 302 frames/s. A high-speed buffer on FPGA termed a transient spectrum recorder continuously records the latest 5 s of raw data. Both the playback of absorption spectrum parameters and raw data provide a way for a detailed and in-depth understanding of the dynamic combustion process. Experiments were carried out by using an alcohol burner to evaluate the online monitoring and offline playback abilities of the system.
AB - Tunable diode laser absorption spectroscopy (TDLAS) tomography enables online diagnosis of dynamic flames by imaging its temperature variations and exhaust gases, owing to its rapid response. Each tomographic image requires huge laser absorption spectrum data along multiple laser paths. For a high temporal resolution, the data sampling rate needs to be as high as possible which challenges the hardware implementation of parallel data acquisition (DAQ) of multiple channels. An online TDLAS tomography system was designed on field programmable gate array (FPGA) and PC for temperature and gas mole fraction distribution measurement. An on-chip parameter extraction module based on digital lock-in amplifier (DLIA) extracts absorption spectrum parameters at 1000 frames/s (FPS), and the framerate of real-time reconstruction on the host PC can reach up to 302 frames/s. A high-speed buffer on FPGA termed a transient spectrum recorder continuously records the latest 5 s of raw data. Both the playback of absorption spectrum parameters and raw data provide a way for a detailed and in-depth understanding of the dynamic combustion process. Experiments were carried out by using an alcohol burner to evaluate the online monitoring and offline playback abilities of the system.
KW - Combustion diagnosis
KW - data acquisition (DAQ) system
KW - digital signal processing
KW - field programmable gate array (FPGA)
KW - tunable diode laser absorption spectroscopy (TDLAS) tomography
UR - https://www.scopus.com/pages/publications/85139520165
U2 - 10.1109/TIM.2022.3208668
DO - 10.1109/TIM.2022.3208668
M3 - 文章
AN - SCOPUS:85139520165
SN - 0018-9456
VL - 71
JO - IEEE Transactions on Instrumentation and Measurement
JF - IEEE Transactions on Instrumentation and Measurement
M1 - 2006210
ER -