跳到主要导航 跳到搜索 跳到主要内容

90 Y 核药制备中90 Sr 活度测量装置的模拟研究

  • Shuquan Wei
  • , Wei Cheng
  • , Weiwei Qu*
  • , Gaolong Zhang
  • *此作品的通讯作者
  • Soochow University
  • Nanjing University of Aeronautics and Astronautics

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

To quantify 90Sr content and radioactivity in the preparation of 90Y nuclear propellant, this paper presents a method of using charged particle deflection in a magnetic field and discusses the influence of various parameters on the detection result. The Geant4 toolkit based on the Monte Carlo method was used to simulate the detection of emitted electrons. Two kinds of launch models, i. e., point-source and volume-source, were constructed for the simulation. The number of emitted β particles deflected by the magnetic field was detected by two detectors, and the contents of the two nuclides were deduced according to the characteristics of electron energy spectra of 90Y and 90Sr nuclides. The result verifies that the content of 90Sr in 90Y microspheres can be theoretically determined by this method; however, the method accuracy significantly depends on the type of detector used. Moreover, the accuracy can be improved by optimizing several parameters, including the type of material, size, and placement of the detector.

投稿的翻译标题A simulation study on 90 Sr radioactivity measurement in 90 Y during the nuclear medicine preparation
源语言繁体中文
页(从-至)1598-1603
页数6
期刊Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University
卷43
期11
DOI
出版状态已出版 - 11月 2022

关键词

  • Geant4
  • Monte Carlo
  • Sr radioactivity
  • Y microspheres
  • magnet spectrometer
  • nuclear medicine
  • nuclide content
  • β decay

学术指纹

探究 '90 Y 核药制备中90 Sr 活度测量装置的模拟研究' 的科研主题。它们共同构成独一无二的学术指纹。

引用此