TY - GEN
T1 - Study on the capacitors of reference partial discharge calibritor
AU - Na, Liu
AU - Zheng, Qian
AU - Jiawei, Chen
AU - Mei, Yin
PY - 2010
Y1 - 2010
N2 - Capacitors with high quality of frequency characteristics are necessary for reference partial discharge(PD) calibrator. For this purpose, two methods to measure the internal inductance of three-terminal capacitors have been discussed. One is by LCR meter, the other method is based on the underdamped response of a series RLC circuit. Measurement results show that the latter is better.
AB - Capacitors with high quality of frequency characteristics are necessary for reference partial discharge(PD) calibrator. For this purpose, two methods to measure the internal inductance of three-terminal capacitors have been discussed. One is by LCR meter, the other method is based on the underdamped response of a series RLC circuit. Measurement results show that the latter is better.
UR - https://www.scopus.com/pages/publications/77956641181
U2 - 10.1109/CPEM.2010.5544153
DO - 10.1109/CPEM.2010.5544153
M3 - 会议稿件
AN - SCOPUS:77956641181
SN - 9781424467952
T3 - CPEM Digest (Conference on Precision Electromagnetic Measurements)
SP - 680
EP - 681
BT - 2010 Conference on Precision Electromagnetic Measurements, CPEM 2010
T2 - 2010 Conference on Precision Electromagnetic Measurements, CPEM 2010
Y2 - 13 June 2010 through 18 June 2010
ER -