摘要
Analyzing the various problems of current steady-state operation life test standard, it is pointed out that, not measuring and controlling, transistor junction temperature in current transistor steady-state operation life test can lead to fatal inaccuracy of the test results. To increase the accuracy of the test method, a steady-state operation life test method with additional measuring and strictly controlling transistor junction temperature, in the highest temperature range, is given. Bipolar transistors of the type of 3DD820 and 3DD15D (with F2 metal-pack) are taken as an example in the study to verify the method of controllable junction temperature. Analyzing result of simulated experiment data shows that the test method can increase availably the accuracy of the transistor steady-state operation life test method.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 696-699 |
| 页数 | 4 |
| 期刊 | Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics |
| 卷 | 31 |
| 期 | 6 |
| 出版状态 | 已出版 - 6月 2005 |
指纹
探究 'Study of transistor steady-state operation life test by method of controllable junction temperature' 的科研主题。它们共同构成独一无二的指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver