Study of oxygen transport and thrombosis risk with membrane oxygenators

投稿的翻译标题: 膜式氧合器中氧气传输与血栓风险的研究
  • Beihang University

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

To build a thrombosis risk assessment model applicable to oxygenators and investigate the effects of oxygenator external configuration and membrane filaments macroscopic parameters on the performances of cylindrical oxygenators. A thrombosis driven by surface contact, shear stress, and anticoagulant drugs, and considering the effects of these factors on platelet, coagulation factor, and hemostatic protein function risk model was developed and validated with clinical oxygenators. The thrombosis model combined with a pressure loss model and an oxygen partial pressure model was used to assess the effect of the external structure and macroscopic parameters of the membrane filaments (height and thickness) on the performance of the cylindrical oxygenator. The cylindrical oxygenator center circular inflow manner and tangential outflow manner from the middle region of the outside benefit the overall performance of the oxygenator (reduced pressure loss and thrombosis risk). Increasing the radial thickness of the oxygenator membrane filaments significantly increased the oxygen exchange ability of the oxygenator and reduced the thrombosis risk compared to increasing the axial height, but with a smaller increase in pressure loss. Contact activation leading to thrombin production contributes significantly to oxygenator thrombosis. The oxygenator has little effect on platelet receptor function. Thrombosis in cylindrical oxygenators tends to form in the flow-flow/border impingement regions because of the high concentration of coagulation factors and long residence times in these regions. A thrombosis risk assessment model applicable to oxygenators was developed. We disclosed the mechanism of the impact of oxygenator external configuration and membrane filaments macroscopic parameters on its internal flow fields, the risk of thrombosis, and the efficiency of gas exchange, which are useful for the design and optimization of cylindrical oxygenators.

投稿的翻译标题膜式氧合器中氧气传输与血栓风险的研究
源语言英语
期刊论文编号624528
期刊Acta Mechanica Sinica/Lixue Xuebao
卷41
期11
DOI
出版状态已出版 - 11月 2025

学术指纹

探究 '膜式氧合器中氧气传输与血栓风险的研究' 的科研主题。它们共同构成独一无二的学术指纹。

引用此