TY - GEN
T1 - Research on test of Anti-G Suits airbag Pressure
AU - Yi, Ding
AU - Zhu, Zhaowei
AU - Yandong, Wang
AU - Zhongji, Zhang
AU - Kaiyuan, Song
AU - Li, Ding
N1 - Publisher Copyright:
© Springer International Publishing AG, part of Springer Nature 2018.
PY - 2018
Y1 - 2018
N2 - In order to solve the problem of overloading, the common international practice is to use anti-load equipment (anti-load suits). This article focuses on the role of capsule anti-Dutch suit pressure on pilots. Considering the actual situation of overload, if the absolute value of overload is too large and the applied pressure is too small, it will lead to imperfect overload and cause flight safety hazard. Conversely, if the absolute value of overload is too small and the pressure exerted on it will lead to blood circulation disorder Serious or even tissue necrosis occurs. Therefore, it is of great value to study the numerical relationship between cystic pressure and body pressure. In this paper, the relationship between capsule anti-static clothing pressure and body pressure is explored by experimental method. Wearable body surface pressure measurement device is designed based on the membrane pressure sensor. The research shows that: (1) there is a correlation between capsule pressure and body pressure, the absolute value of the body pressure can be estimated by the capsule pressure; (2) The corresponding relationship between the capsule pressure and the body pressure of different parts is different, The corresponding relationship between gauge pressure is also a certain difference.
AB - In order to solve the problem of overloading, the common international practice is to use anti-load equipment (anti-load suits). This article focuses on the role of capsule anti-Dutch suit pressure on pilots. Considering the actual situation of overload, if the absolute value of overload is too large and the applied pressure is too small, it will lead to imperfect overload and cause flight safety hazard. Conversely, if the absolute value of overload is too small and the pressure exerted on it will lead to blood circulation disorder Serious or even tissue necrosis occurs. Therefore, it is of great value to study the numerical relationship between cystic pressure and body pressure. In this paper, the relationship between capsule anti-static clothing pressure and body pressure is explored by experimental method. Wearable body surface pressure measurement device is designed based on the membrane pressure sensor. The research shows that: (1) there is a correlation between capsule pressure and body pressure, the absolute value of the body pressure can be estimated by the capsule pressure; (2) The corresponding relationship between the capsule pressure and the body pressure of different parts is different, The corresponding relationship between gauge pressure is also a certain difference.
KW - Anti-G suits
KW - Pilot
KW - Pressure
KW - Pressure test experiment
UR - https://www.scopus.com/pages/publications/85050340943
U2 - 10.1007/978-3-319-91122-9_30
DO - 10.1007/978-3-319-91122-9_30
M3 - 会议稿件
AN - SCOPUS:85050340943
SN - 9783319911212
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 352
EP - 366
BT - Engineering Psychology and Cognitive Ergonomics - 15th International Conference, EPCE 2018, Held as Part of HCI International 2018, Proceedings
A2 - Harris, Don
PB - Springer Verlag
T2 - 15th International Conference on Engineering Psychology and Cognitive Ergonomics, EPCE 2018 Held as Part of HCI International 2018
Y2 - 15 July 2018 through 20 July 2018
ER -