TY - JOUR
T1 - Research on spatial resolution in cardiac source imaging for multiple measurement modes using a realistic multi-tissue human model
AU - Wang, Yanmei
AU - Wang, Huidong
AU - Yang, Yanfei
AU - Liu, Zhanyi
AU - Pang, Jiaojiao
AU - Cui, Peiling
AU - Xiang, Min
N1 - Publisher Copyright:
© 2024
PY - 2025/2/15
Y1 - 2025/2/15
N2 - Magnetocardiography (MCG) and electrocardiography (ECG) are noninvasive techniques that reflect cardiac electrical activity. Combined MCG and ECG (MECG) integrates both measurements, and due to technological advancements, vector MCG (vMCG) is now possible. Although all four modes—MCG, ECG, MECG, and vMCG—are used in cardiac source imaging, their spatial resolutions have not been systematically studied. This study evaluates these modes using a resolution matrix based on a realistic multi-tissue human model, analyzing their dependence on source direction, location, and signal-to-noise ratio. Results show that MECG and vMCG significantly reduce dependence on these factors, with vMCG offering superior spatial resolution. However, its advantage lessens as SNR decreases. Our findings suggest that MECG and vMCG enhance spatial resolution in cardiac source imaging, making them promising options for future research.
AB - Magnetocardiography (MCG) and electrocardiography (ECG) are noninvasive techniques that reflect cardiac electrical activity. Combined MCG and ECG (MECG) integrates both measurements, and due to technological advancements, vector MCG (vMCG) is now possible. Although all four modes—MCG, ECG, MECG, and vMCG—are used in cardiac source imaging, their spatial resolutions have not been systematically studied. This study evaluates these modes using a resolution matrix based on a realistic multi-tissue human model, analyzing their dependence on source direction, location, and signal-to-noise ratio. Results show that MECG and vMCG significantly reduce dependence on these factors, with vMCG offering superior spatial resolution. However, its advantage lessens as SNR decreases. Our findings suggest that MECG and vMCG enhance spatial resolution in cardiac source imaging, making them promising options for future research.
KW - Cardiac source imaging
KW - ECG
KW - MCG
KW - MCG–ECG fusion
KW - Spatial resolution
KW - Vector MCG
UR - https://www.scopus.com/pages/publications/85211979283
U2 - 10.1016/j.measurement.2024.116353
DO - 10.1016/j.measurement.2024.116353
M3 - 文章
AN - SCOPUS:85211979283
SN - 0263-2241
VL - 243
JO - Measurement: Journal of the International Measurement Confederation
JF - Measurement: Journal of the International Measurement Confederation
M1 - 116353
ER -