TY - JOUR
T1 - Quasi-constant rotational stiffness characteristic for cross-spring pivots in high precision measurement of unbalance moment
AU - Bi, Shusheng
AU - Zhang, Shuqing
AU - Zhao, Hongzhe
N1 - Publisher Copyright:
© 2015 Elsevier Inc. All rights reserved.
PY - 2016/1
Y1 - 2016/1
N2 - This paper proposes a design method for cross-spring pivots with quasi-constant rotational stiffness in the field of unbalanced moment measurement. To achieve high precision measurement of unbalance moment, the relationship between instrument sensitivity and the rotational stiffness of the cross-spring pivot is revealed. In order to eliminate the impacts of payload changes on instrument sensitivity, the relationship between geometric parameters and the rotational stiffness of the pivot is studied. Further, cross-spring pivots with quasi-constant rotational stiffness are designed as the rotation unit of a static balancing instrument, while the center shift of pivot takes the minimum value. Certain amount of unbalance moments is measured by the instrument. Experimental studies of the instrument show that the maximum measurement errors of unbalance moments 0.162 g mm, 0.319 g mm and 1.300 g mm are 0.068 g mm, 0.086 g mm and 0.053 g mm, respectively, when the payload ranges from 0 g to 7000 g. The instrument can achieve a relatively high precision measurement and the instrument sensitivity is almost not affected by the changes of payloads. The effectiveness of the method and the stiffness property of the pivot are verified by the experiments. So this kind of pivot has good prospects in unbalance moment measurement.
AB - This paper proposes a design method for cross-spring pivots with quasi-constant rotational stiffness in the field of unbalanced moment measurement. To achieve high precision measurement of unbalance moment, the relationship between instrument sensitivity and the rotational stiffness of the cross-spring pivot is revealed. In order to eliminate the impacts of payload changes on instrument sensitivity, the relationship between geometric parameters and the rotational stiffness of the pivot is studied. Further, cross-spring pivots with quasi-constant rotational stiffness are designed as the rotation unit of a static balancing instrument, while the center shift of pivot takes the minimum value. Certain amount of unbalance moments is measured by the instrument. Experimental studies of the instrument show that the maximum measurement errors of unbalance moments 0.162 g mm, 0.319 g mm and 1.300 g mm are 0.068 g mm, 0.086 g mm and 0.053 g mm, respectively, when the payload ranges from 0 g to 7000 g. The instrument can achieve a relatively high precision measurement and the instrument sensitivity is almost not affected by the changes of payloads. The effectiveness of the method and the stiffness property of the pivot are verified by the experiments. So this kind of pivot has good prospects in unbalance moment measurement.
KW - Cross-spring pivot
KW - Gimbaled device
KW - Instrument sensitivity
KW - Quasi-constant rotational stiffness
KW - Unbalance moment
UR - https://www.scopus.com/pages/publications/84948714264
U2 - 10.1016/j.precisioneng.2015.08.013
DO - 10.1016/j.precisioneng.2015.08.013
M3 - 文章
AN - SCOPUS:84948714264
SN - 0141-6359
VL - 43
SP - 328
EP - 334
JO - Precision Engineering
JF - Precision Engineering
ER -