The xenon pumping speed testing system of the large-diameter external cryopump was designed to meet the plume test requirements for prototype electric propulsion. The flowmeter method was utilized to measure the xenon pumping speed. The test results show that the averaged effective pumping speed of double-cryopumps is 52 200 L/s, and that of single-cryopump is 27 100 L/s. The pumping speed ratio of two configurations is 1.93. It can be concluded that the pumping speed has in linear relationship with the number of cryopump, and the coefficient is irrelevant with the gas type. The averaged effective pumping speed of xenon is less than its nominal pumping speed, and the averaged pumping efficiency is 0.83. Under the identical inflow conditions, the averaged effective pumping speed ratio of nitrogen is 0.53, slightly less than the theoretical pumping speed ratio of 0.55. Consequently, it can be concluded that results assessment of large-diameter external cryopump design index can guide the engineering application, showing certain reference significance.

源语言英语
页(从-至)1731-1736
页数6
期刊Hangkong Dongli Xuebao/Journal of Aerospace Power
30
7
DOI
出版状态已出版 - 1 7月 2015