跳到主要导航 跳到搜索 跳到主要内容

[Primary clinical application of traction reductor for lower limb fracture].

  • Jun qiang Wang*
  • , Lei Hu
  • , Yong gang Su
  • , Chun peng Zhao
  • , Bin bin Wang
  • , Xue dong Zhong
  • , Xiao feng Gong
  • , Jian Zhang
  • , Man yi Wang
  • *此作品的通讯作者
  • Capital Medical University

科研成果: 期刊稿件文章同行评审

摘要

To develop a traction reductor for the reduction of lower limb fractures during the minimally invasive surgery and explore its safety and efficacy. From February 2007 to March 2009, closed or limited open reduction plus percutaneous plate and screw internal-fixation were conducted in 34 patients with fracture of distal femur and tibia metaphysic, among which there were 3 distal femoral fractures (2 33-B, 1 33-C), 14 proximal tibial fractures (9 41-A, 3 41-B, 2 41-C) and 17 distal tibial fractures (9 43-A, 5 43-B, 3 43-C, 2 Gustilo I a), according to the Association for Osteosynthesis-Orthopaedic Trauma Association (AO-OTA) classification. Besides, closed reduction plus interlocking intramedullary nailing on tibial shaft fracture were applied in 36 patients (7 42-A, 21 42-B, 8 42-C, 2 Gustilo I a). All the 70 patients, with an average age of 37.6 years (range: 17 to 63 years) and average time before surgery of 4.7 d (range: 0.7 to 12.0 d), underwent reduction by self-designed traction reductor for lower limb fracture in the surgery. The reduction duration and C-arm fluoroscopy time were recorded. Recovery of the force line of affected limbs after surgery was determined by whether the line from anterior superior iliac spine to the interdigit between the first and second toe-web passed the patella center. And the distance from bilateral anterior superior iliac spine to medial malleolus tip as well as the difference between lower limbs were recorded to determine the recovery of length after surgery. Meanwhile, the varus-valgus and anteroposterior angulations after reduction were measured by AP and lateral X-ray. The reduction duration was 12.7 min (range: 7 to 31 min); X-ray fluoroscopy time, 1.3 min (range: 0.4 to 3.0 min); length difference between both lower limbs (6.5 ± 1.1) mm; and axial alignment difference (7.0 ± 1.8) mm. The X-ray result showed that varus-valgus angle was (2.75 ± 0.16)°; and anteroposterior angulation (5.13 ± 0.51)°. The traction reductor for lower limb fracture could achieve satisfying fracture reduction in the minimally invasive surgery of distal femur, tibia metaphysic and tibial shaft fracture.

源语言英语
页(从-至)1425-1429
页数5
期刊Chinese Journal of Surgery
48
18
出版状态已出版 - 15 9月 2010

指纹

探究 '[Primary clinical application of traction reductor for lower limb fracture].' 的科研主题。它们共同构成独一无二的指纹。

引用此