摘要
This article aims to provide a more accurate calculation method for design of condensing heat exchanger (CHX) through an in-depth discussion about work conditions of the CHX commonly used in temperature and humidity control system. With difference of the simplified configuration of CHX, a mathematical model is given. Specifically, the Log-mean temperature difference (LMTD) method is used in dry conditions, while in wet conditions mass and energy conservation equations are used. The set of equations of the model are solved by using the shooting method provided by Matlab/Simulink program. The results of work conditions and the performances of heat transfer and dehumidification of CHX are determined. Analysis shows that the simulation model can evaluate performances of the CHX in different work conditions reasonably and the results are close to the physical phenomenon. The method raised in this paper is valuable for design and optimization of CHX.
| 源语言 | 英语 |
|---|---|
| 主期刊名 | Proceedings - 6th International Symposium on Heating, Ventilating and Air Conditioning, ISHVAC 2009 |
| 页 | 708-715 |
| 页数 | 8 |
| 出版状态 | 已出版 - 2009 |
| 活动 | 6th International Symposium on Heating, Ventilating and Air Conditioning, ISHVAC 2009 - Nanjing, 中国 期限: 6 11月 2009 → 9 11月 2009 |
出版系列
| 姓名 | Proceedings - 6th International Symposium on Heating, Ventilating and Air Conditioning, ISHVAC 2009 |
|---|---|
| 卷 | 1 |
会议
| 会议 | 6th International Symposium on Heating, Ventilating and Air Conditioning, ISHVAC 2009 |
|---|---|
| 国家/地区 | 中国 |
| 市 | Nanjing |
| 时期 | 6/11/09 → 9/11/09 |
联合国可持续发展目标
此成果有助于实现下列可持续发展目标:
-
可持续发展目标 7 经济适用的清洁能源
指纹
探究 'Performance simulation of condensing heat exchanger in different work conditions' 的科研主题。它们共同构成独一无二的指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver