TY - GEN
T1 - Performance evaluation of the non-linear and linear estimation methods for determining kinetic parameters in dynamic FDG-PET study
AU - Dai, Xiaoqian
AU - Tian, Jie
AU - Chen, Zhe
PY - 2010
Y1 - 2010
N2 - Dynamic positron emission tomography (PET) is a promising diagnostic tool to quantitatively predict biological and physiological changes in vivo through estimation of kinetic parameters. In this work, several popular linear and non-linear estimation methods for determining kinetic parameters using PET imaging with Fluorine-18 fluorodeoxyglucose ([18F]FDG) are compared and evaluated. The simulation studies are presented. The linear estimation methods include linear least squares (LLS), generalized linear least squares (GLLS) and total least squares (TLS), while the non-linear estimation methods include non-linear least squares (NLS), weighted nonlinear least squares using noisy tissue time activity data (WNLS-N), weighted non-linear least squares using noise-free tissue time activity data (WNLS-NF) and iteratively re-weighted non-linear least squares (IRWNLS). There are several findings: 1. Compared with non-linear estimation methods, GLLS performs well when noise level is low, but worse especially in determining k3 and k4 when noise level is high. What's more, GLLS does not show obvious advantage in running time. 2. The choice of weights plays an important role in nonlinear estimation methods. Weighting using noisy data should be avoided. WNLS-NF and IRWNLS perform best. Since the noise-free data can not be obtained in clinical and IRWNLS is time-consuming, NLS is most recommended. 3. Non-linear estimation methods are prone to produce lower-biased, higher-precision parameter estimates, however, also more easily affected by noise. Linear estimation methods are prone to be more biased, however, much more computational efficient and noise robust.
AB - Dynamic positron emission tomography (PET) is a promising diagnostic tool to quantitatively predict biological and physiological changes in vivo through estimation of kinetic parameters. In this work, several popular linear and non-linear estimation methods for determining kinetic parameters using PET imaging with Fluorine-18 fluorodeoxyglucose ([18F]FDG) are compared and evaluated. The simulation studies are presented. The linear estimation methods include linear least squares (LLS), generalized linear least squares (GLLS) and total least squares (TLS), while the non-linear estimation methods include non-linear least squares (NLS), weighted nonlinear least squares using noisy tissue time activity data (WNLS-N), weighted non-linear least squares using noise-free tissue time activity data (WNLS-NF) and iteratively re-weighted non-linear least squares (IRWNLS). There are several findings: 1. Compared with non-linear estimation methods, GLLS performs well when noise level is low, but worse especially in determining k3 and k4 when noise level is high. What's more, GLLS does not show obvious advantage in running time. 2. The choice of weights plays an important role in nonlinear estimation methods. Weighting using noisy data should be avoided. WNLS-NF and IRWNLS perform best. Since the noise-free data can not be obtained in clinical and IRWNLS is time-consuming, NLS is most recommended. 3. Non-linear estimation methods are prone to produce lower-biased, higher-precision parameter estimates, however, also more easily affected by noise. Linear estimation methods are prone to be more biased, however, much more computational efficient and noise robust.
KW - Compartment model
KW - Linear estimation methods
KW - Non-linear estimation methods
KW - Parameter estimation
UR - https://www.scopus.com/pages/publications/77953306223
U2 - 10.1117/12.843796
DO - 10.1117/12.843796
M3 - 会议稿件
AN - SCOPUS:77953306223
SN - 9780819480279
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2010 - Biomedical Applications in Molecular, Structural, and Functional Imaging
T2 - Medical Imaging 2010 - Biomedical Applications in Molecular, Structural, and Functional Imaging
Y2 - 14 February 2010 through 16 February 2010
ER -