跳到主要导航 跳到搜索 跳到主要内容

Parametric finite element method design of flexural vibration holder for vibration cutting

  • Beihang University

科研成果: 期刊稿件文章同行评审

摘要

Based on the structural characteristics of vibration cutting holder and its basic equation of dynamic problem, the parametric finite element dynamic model for the symmetrical three-step vibration holder is given. The 3D curves displaying the variations of the resonance frequency and nodal pitch with the tool holder sizes are drawn by the computer based on the redevelopment of the software ANSYS by using ANSYS Parametric Design Language (APDL), and the parametric finite element method design of the symmetrical three-step flexural vibration holder is achieved. The calculating error of resonance frequency and nodal pitch with the present method are 2.5% and 3.5% respectively, and with the analytic method the corresponding calculating errors are 3% and 5% respectively in the same size range of the holder, it demonstrates that the present method can show better agreement with the experimental results, and it is a more convenient and accurate method for designing flexural vibration holder.

源语言英语
页(从-至)516-520
页数5
期刊Shengxue Xuebao/Acta Acustica
29
6
出版状态已出版 - 11月 2004