TY - JOUR
T1 - Parameter Optimization for the Induction Magnetometer of 10 kHz to 100 kHz
AU - Li, Wenbin
AU - Huang, Pu
AU - Ding, Zhongyi
AU - Xie, Yuedong
N1 - Publisher Copyright:
© 2013 IEEE.
PY - 2022
Y1 - 2022
N2 - The induction magnetometers are widely applied for magnetotelluric detection due to the characteristics of wide frequency band, large detection depth range and small size. However, the key part of the induction magnetometers - the magnetic core has eddy current loss and hysteresis loss, which significantly affects the sensitivity of the induction magnetometers. In order to improve the sensitivity of the induction magnetometers at high frequencies, this paper investigates various parameters related to the performance of the induction magnetometers working at 10 kHz to 100 kHz. Moreover, optimization method is proposed to realize the development of a wide-band, high-sensitivity, and low-noise induction magnetometer. First of all, the parameters related to the sensitivity of the sensor are investigated according to the law of electromagnetic induction. A three-dimensional finite element (3D-FE) simulation model was established to study the influence of various parameters of induction magnetometers. In addition, an analysis method combining orthogonal experiment and response surface method is adopted to reduce the quantity of computations and improve the efficiency of analysis. The orthogonal experiment is able to obtain preliminary optimal parameters with only a small amount of computation results. Based on the results of the orthogonal experiment, the response surface method is used to illustrate the relationship between the sensor parameters and losses, and hence the optimal sensor parameters can be obtained. Finally, the model is verified by other sets of simulations, and the results show the regression coefficient of the model R{2}=0.9735 , indicating the effectiveness of the proposed model.
AB - The induction magnetometers are widely applied for magnetotelluric detection due to the characteristics of wide frequency band, large detection depth range and small size. However, the key part of the induction magnetometers - the magnetic core has eddy current loss and hysteresis loss, which significantly affects the sensitivity of the induction magnetometers. In order to improve the sensitivity of the induction magnetometers at high frequencies, this paper investigates various parameters related to the performance of the induction magnetometers working at 10 kHz to 100 kHz. Moreover, optimization method is proposed to realize the development of a wide-band, high-sensitivity, and low-noise induction magnetometer. First of all, the parameters related to the sensitivity of the sensor are investigated according to the law of electromagnetic induction. A three-dimensional finite element (3D-FE) simulation model was established to study the influence of various parameters of induction magnetometers. In addition, an analysis method combining orthogonal experiment and response surface method is adopted to reduce the quantity of computations and improve the efficiency of analysis. The orthogonal experiment is able to obtain preliminary optimal parameters with only a small amount of computation results. Based on the results of the orthogonal experiment, the response surface method is used to illustrate the relationship between the sensor parameters and losses, and hence the optimal sensor parameters can be obtained. Finally, the model is verified by other sets of simulations, and the results show the regression coefficient of the model R{2}=0.9735 , indicating the effectiveness of the proposed model.
KW - Induction magnetometers
KW - loss analysis
KW - orthogonal experiment
KW - response surface method
KW - three-dimensional finite element simulation model
UR - https://www.scopus.com/pages/publications/85125321364
U2 - 10.1109/ACCESS.2022.3153070
DO - 10.1109/ACCESS.2022.3153070
M3 - 文章
AN - SCOPUS:85125321364
SN - 2169-3536
VL - 10
SP - 21169
EP - 21177
JO - IEEE Access
JF - IEEE Access
ER -