跳到主要导航 跳到搜索 跳到主要内容

Optimized gas pressure of an Rb vapor cell in a single-beam SERF magnetometer

科研成果: 期刊稿件文章同行评审

摘要

We present a theoretical and experimental study of a single-beam spin-exchange relaxation-free magnetometer in 87Rb vapor cells under different nitrogen gas pressures. The spin relaxation rate is a key component to limit the magnetic sensitivity, and the zero-field resonance method was used to measure the spin relaxation rates of different alkali metal cells. Simultaneously, in a single-beam spin-exchange-relaxation-free (SERF) magnetometer, we demonstrated that the fundamental magnetic field sensitivity was also limited by the pumping light intensity. Based on our theoretical analysis and experimental results, we determined the optimal pumping light intensity and optimal gas pressure. We experimentally demonstrated that the magnetic field sensitivity was 8.89

源语言英语
页(从-至)336-348
页数13
期刊Optics Express
30
1
DOI
出版状态已出版 - 3 1月 2022

指纹

探究 'Optimized gas pressure of an Rb vapor cell in a single-beam SERF magnetometer' 的科研主题。它们共同构成独一无二的指纹。

引用此