TY - JOUR
T1 - Optimized design of cubic grid coil system with high space utilization ratio for weak biomagnetic signal measurement
AU - Dou, Shuai
AU - Liu, Xikai
AU - Deng, Ya
AU - Wen, Tong
AU - Han, Bangcheng
N1 - Publisher Copyright:
© 2024 Elsevier Ltd
PY - 2025/2
Y1 - 2025/2
N2 - The uniform field coils with large uniform region are important for improving the resolution in bio-magnetic signal measurements. The traditional coil design methods suffer from small space utilization ratio which limits the mobility and accuracy of bio-magnetic signal measurements. In this paper, a novel cubic grid coil (CGC) design method is presented, with significantly improved space utilization ratio and simple structure. The iterative fastest current drop method (IFCD) is proposed to simplify coil structure, thus ensuring the controllability of the cubic grid coil system. The superiority of CGCs has been demonstrated by finite element simulations and a series of experiments. The space utilization ratio of CGCs reaches 22.4% while maintaining 2% inhomogeneity, improved by about 6 times compared with traditional coils. Furthermore, the CGC-based system for directly eliminating the geomagnetic field achieves a low residual magnetic field noise of 29.7 pT/Hz/1/2 at 1 Hz. The CGCs can provide new ideas for high-resolution, lightweight mobile measurements of weak bio-magnetic signals in the human body.
AB - The uniform field coils with large uniform region are important for improving the resolution in bio-magnetic signal measurements. The traditional coil design methods suffer from small space utilization ratio which limits the mobility and accuracy of bio-magnetic signal measurements. In this paper, a novel cubic grid coil (CGC) design method is presented, with significantly improved space utilization ratio and simple structure. The iterative fastest current drop method (IFCD) is proposed to simplify coil structure, thus ensuring the controllability of the cubic grid coil system. The superiority of CGCs has been demonstrated by finite element simulations and a series of experiments. The space utilization ratio of CGCs reaches 22.4% while maintaining 2% inhomogeneity, improved by about 6 times compared with traditional coils. Furthermore, the CGC-based system for directly eliminating the geomagnetic field achieves a low residual magnetic field noise of 29.7 pT/Hz/1/2 at 1 Hz. The CGCs can provide new ideas for high-resolution, lightweight mobile measurements of weak bio-magnetic signals in the human body.
KW - Iterative fastest current drop method
KW - Precision magnetic field compensation
KW - Ultra-high space utilization ratio
KW - Uniform cubic grid coil design
KW - Weak biomagnetic measurement
UR - https://www.scopus.com/pages/publications/85203638478
U2 - 10.1016/j.measurement.2024.115697
DO - 10.1016/j.measurement.2024.115697
M3 - 文章
AN - SCOPUS:85203638478
SN - 0263-2241
VL - 241
JO - Measurement: Journal of the International Measurement Confederation
JF - Measurement: Journal of the International Measurement Confederation
M1 - 115697
ER -