跳到主要导航 跳到搜索 跳到主要内容

Optimization of magnetic-grating-like stroke-sensing cylinder based on response quality evaluation algorithm

  • Yanqing Guo
  • , Lu Liu
  • , Yongling Fu*
  • , Chuangchuang Li
  • , Liang Guo
  • *此作品的通讯作者
  • North University of China

科研成果: 期刊稿件文章同行评审

摘要

The measurement of hydraulic cylinder displacement has been addressed from different fields. The detection principle of magnetic grating is able to realize the high integration and accuracy. In this paper, a signal response quality evaluation algorithm for devising and optimizing a high-accuracy displacement measuring system is proposed. On the basic of signal response quality evaluation method, structure variables are optimized to enhance the working performance. By defining the parameters, an optimum structure cylinder prototype is made and tested to provide better estimates. Experimental results on working characteristic are presented to verify the effectiveness of the optimized structure. The efficiency of the proposed signal response quality evaluation function is therefore demonstrated through the working performance.

源语言英语
文章编号7046390
期刊Journal of Sensors
2018
DOI
出版状态已出版 - 2018

指纹

探究 'Optimization of magnetic-grating-like stroke-sensing cylinder based on response quality evaluation algorithm' 的科研主题。它们共同构成独一无二的指纹。

引用此