TY - JOUR
T1 - Optimal Design of Highly Uniform Magnetic Field Coils Under High-Permeability Magnetic Shields in Miniaturized NMR Sensors
AU - Jie, Shaofeng
AU - Liu, Zhanchao
AU - Zhang, Shuai
AU - Wang, Jingsong
AU - Wu, Zekun
N1 - Publisher Copyright:
© 2024 IEEE.
PY - 2024
Y1 - 2024
N2 - Magnetic coils in the magnetic shield are combined to generate a precise and uniform magnetic field for nuclear magnetic resonance (NMR) sensors and shield against the disturbance of the external magnetic field. However, the effect of magnetic shields made of high-permeability materials on coil constants and magnetic field uniformity has become a significant issue for miniaturized NMR sensors. We proposed a novel optimal design method for the magnetic field coils based on the modified Green function of the ferromagnetic boundary and introduced an improved genetic algorithm (IGA) to improve the optimal efficiency. First, the coupling effect of the radius and height of the coil and the magnetic shield was analyzed. Then, a solenoid coil system in the cylindrical magnetic shield was designed and fabricated. In the experiment, compared with the traditional method, the coupling coefficient of the coil constant of the coil designed by the proposed method was reduced of 10.45%. The maximum magnetic field error in the target region reached a significant reduction by two orders of magnitude in calculations and experiments. Moreover, the optimized coils applied to the NMR sensor enhanced the transverse nuclear spin relaxation time of 129Xe by 44.32%, which has the potential to improve the sensor performance.
AB - Magnetic coils in the magnetic shield are combined to generate a precise and uniform magnetic field for nuclear magnetic resonance (NMR) sensors and shield against the disturbance of the external magnetic field. However, the effect of magnetic shields made of high-permeability materials on coil constants and magnetic field uniformity has become a significant issue for miniaturized NMR sensors. We proposed a novel optimal design method for the magnetic field coils based on the modified Green function of the ferromagnetic boundary and introduced an improved genetic algorithm (IGA) to improve the optimal efficiency. First, the coupling effect of the radius and height of the coil and the magnetic shield was analyzed. Then, a solenoid coil system in the cylindrical magnetic shield was designed and fabricated. In the experiment, compared with the traditional method, the coupling coefficient of the coil constant of the coil designed by the proposed method was reduced of 10.45%. The maximum magnetic field error in the target region reached a significant reduction by two orders of magnitude in calculations and experiments. Moreover, the optimized coils applied to the NMR sensor enhanced the transverse nuclear spin relaxation time of 129Xe by 44.32%, which has the potential to improve the sensor performance.
KW - Genetic algorithm
KW - magnetic coupling effect
KW - nuclear magnetic resonance (NMR) sensors
KW - permalloy magnetic shield
KW - uniform magnetic field coils
UR - https://www.scopus.com/pages/publications/85207120403
U2 - 10.1109/TIM.2024.3472769
DO - 10.1109/TIM.2024.3472769
M3 - 文章
AN - SCOPUS:85207120403
SN - 0018-9456
VL - 73
JO - IEEE Transactions on Instrumentation and Measurement
JF - IEEE Transactions on Instrumentation and Measurement
M1 - 4509410
ER -