TY - JOUR
T1 - Numerical simulation of aircraft thermal anti-icing system based on a tight-coupling method
AU - Bu, Xueqin
AU - Lin, Guiping
AU - Shen, Xiaobin
AU - Hu, Zhongliang
AU - Wen, Dongsheng
N1 - Publisher Copyright:
© 2019
PY - 2020/2
Y1 - 2020/2
N2 - Considering the influence of surface temperature distribution on air convective heat transfer coefficient, the robust tight-coupling method is firstly developed for aircraft thermal anti-icing simulations under icing conditions. To include the effects of the impinging water droplets on the conjugate heat transfer of thermal anti-icing systems, the Messinger thermodynamic model of runback water film is modified and added to the tightly coupled calculation of the external air flow and the internal solid skin heat conduction. Numerical simulations are carried out on an electro-thermal anti-icing system under both dry air and icing conditions, and the main conclusions below can be drawn. First, convective heat transfer coefficient changes slightly with surface temperature near the leading edge, but is obviously affected by temperature distribution in the downstream area. Second, the anti-icing temperature deviations between the predicted value and the experiment date are acceptable and comparable to the calculation results in the literature, verifying the feasibility and effectiveness of the tight-coupling method. Third, compared with the traditional decoupled loose-coupling method, the robust tight-coupling anti-icing method successfully captures the effect of surface temperature on convective heat transfer coefficient, and predicts higher temperature with lower drop rate on the downstream surfaces.
AB - Considering the influence of surface temperature distribution on air convective heat transfer coefficient, the robust tight-coupling method is firstly developed for aircraft thermal anti-icing simulations under icing conditions. To include the effects of the impinging water droplets on the conjugate heat transfer of thermal anti-icing systems, the Messinger thermodynamic model of runback water film is modified and added to the tightly coupled calculation of the external air flow and the internal solid skin heat conduction. Numerical simulations are carried out on an electro-thermal anti-icing system under both dry air and icing conditions, and the main conclusions below can be drawn. First, convective heat transfer coefficient changes slightly with surface temperature near the leading edge, but is obviously affected by temperature distribution in the downstream area. Second, the anti-icing temperature deviations between the predicted value and the experiment date are acceptable and comparable to the calculation results in the literature, verifying the feasibility and effectiveness of the tight-coupling method. Third, compared with the traditional decoupled loose-coupling method, the robust tight-coupling anti-icing method successfully captures the effect of surface temperature on convective heat transfer coefficient, and predicts higher temperature with lower drop rate on the downstream surfaces.
KW - Aircraft icing
KW - Conjugate heat transfer
KW - Electro-thermal anti-icing system
KW - Numerical simulation
KW - Tight-coupling method
UR - https://www.scopus.com/pages/publications/85076744996
U2 - 10.1016/j.ijheatmasstransfer.2019.119061
DO - 10.1016/j.ijheatmasstransfer.2019.119061
M3 - 文章
AN - SCOPUS:85076744996
SN - 0017-9310
VL - 148
JO - International Journal of Heat and Mass Transfer
JF - International Journal of Heat and Mass Transfer
M1 - 119061
ER -