Novel correction method for X-ray beam energy fluctuation of high energy DR system with a linear detector

  • Min Yang*
  • , Hao Chen
  • , Fan Yong Meng
  • , Dong Bo Wei
  • *此作品的通讯作者
  • China Academy of Engineering Physics
  • CAS - Institute of Process Engineering
  • Beihang University

科研成果: 期刊稿件文章同行评审

摘要

A high energy digital radiography (DR) testing system has generated diverse scientific and technological interest in the field of industrial non-destructive testing. However, due to the limitations of manufacturing technology for accelerators, an energy fluctuation of the X-ray beam exists and leads to bright and dark streak artifacts in the DR image. Here we report the utilization of a new software-based method to correct the fluctuation artifacts. The correction method is performed using a high pass filtering operation to extract the high frequency information that reflects the X-ray beam energy fluctuation, and then subtracting it from the original image. Our experimental results show that this method is able to rule out the artifacts effectively and is readily implemented on a practical scanning system.

源语言英语
页(从-至)1074-1078
页数5
期刊Chinese Physics C