We report the prediction of the random walk coefficient of a solid-core single-mode polarization-maintaining photonic interferometer fiber optic gyroscope, a novel sensor that exhibits reduced thermal sensitivity owing to the stable temperature coefficient use of a photonic fiber. The random walk coefficient of the photonic interferometer fiber optic gyroscope is limited by detector thermal noise for detected powers under 1 μW and excess noise above 1 μW. Above this power level, the random walk coefficient is found to be independent of detected power and asymptotically to be 0. 0029°/. This result is verified by the experiment.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 284-286 |
| 页数 | 3 |
| 期刊 | Optical Review |
| 卷 | 18 |
| 期 | 3 |
| DOI | |
| 出版状态 | 已出版 - 5月 2011 |