跳到主要导航 跳到搜索 跳到主要内容

Neutron collimator design of neutron radiography based on the BNCT facility

  • Xiao Peng Yang
  • , Bo Xiang Yu*
  • , Yi Guo Li
  • , Dan Peng
  • , Jin Lu
  • , Gao Long Zhang
  • , Hang Zhao
  • , Ai Wu Zhang
  • , Chun Yang Li
  • , Wan Jin Liu
  • , Tao Hu
  • , Jun Guang Lü
  • *此作品的通讯作者
  • Beihang University
  • CAS - Institute of High Energy Physics
  • China National Nuclear Corporation
  • University of South China

科研成果: 期刊稿件文章同行评审

摘要

For the research of CCD neutron radiography, a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy (BNCT) reactor. Based on the Geant4 simulations, the preliminary choice of the size of the collimator was determined. The materials were selected according to the literature data. Then, a collimator was constructed and tested on site. The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0×10 6 n/cm2/s, the maximum collimation ratio (L/D) is 58, the Cd-ratio(Mn) is 160 and the diameter of collimator end is 10 cm. This neutron collimator is considered to be applicable for neutron radiography.

源语言英语
文章编号28201
期刊Chinese Physics C
38
2
DOI
出版状态已出版 - 2月 2014

指纹

探究 'Neutron collimator design of neutron radiography based on the BNCT facility' 的科研主题。它们共同构成独一无二的指纹。

引用此