TY - JOUR
T1 - Multispectral hybrid Cerenkov luminescence tomography based on the finite element SPn method
AU - Liu, Haixiao
AU - Yang, Xin
AU - Song, Tianming
AU - Bao, Chengpeng
AU - Shi, Liangliang
AU - Hu, Zhenhua
AU - Wang, Kun
AU - Tian, Jie
N1 - Publisher Copyright:
© 2015 Society of Photo-Optical Instrumentation Engineers (SPIE).
PY - 2015/8/1
Y1 - 2015/8/1
N2 - Cerenkov luminescence tomography (CLT) is a promising tool that enables three-dimensional noninvasive in vivo detection of radiopharmaceuticals. Conventionally, multispectral information and diffusion theory were introduced to achieve whole-body tomographic reconstruction. However, the diffusion theory inevitably causes systematic error in blue bands of the electromagnetic spectrum due to high-tissue absorption, and CL has a blue-weighted broad spectrum. Therefore, it is challenging to improve the accuracy of CLT. The performance of the n-order simplified spherical harmonics approximation (SPn) in different spectra is evaluated, and a multispectral hybrid CLT based on the combination of different SPn models is proposed to handle the Cerenkov photon transport problem in complex media. The in vivo xenograft experiment shows that this approach can effectively improve the quality and accuracy of the reconstructed light source. We believe that the new reconstruction method will advance the development of CLT for more in vivo imaging applications.
AB - Cerenkov luminescence tomography (CLT) is a promising tool that enables three-dimensional noninvasive in vivo detection of radiopharmaceuticals. Conventionally, multispectral information and diffusion theory were introduced to achieve whole-body tomographic reconstruction. However, the diffusion theory inevitably causes systematic error in blue bands of the electromagnetic spectrum due to high-tissue absorption, and CL has a blue-weighted broad spectrum. Therefore, it is challenging to improve the accuracy of CLT. The performance of the n-order simplified spherical harmonics approximation (SPn) in different spectra is evaluated, and a multispectral hybrid CLT based on the combination of different SPn models is proposed to handle the Cerenkov photon transport problem in complex media. The in vivo xenograft experiment shows that this approach can effectively improve the quality and accuracy of the reconstructed light source. We believe that the new reconstruction method will advance the development of CLT for more in vivo imaging applications.
KW - Cerenkov luminescence tomography
KW - diffusion theory
KW - multispectral
KW - spherical harmonics approximation
UR - https://www.scopus.com/pages/publications/84939240136
U2 - 10.1117/1.JBO.20.8.086007
DO - 10.1117/1.JBO.20.8.086007
M3 - 文章
C2 - 26271053
AN - SCOPUS:84939240136
SN - 1083-3668
VL - 20
JO - Journal of Biomedical Optics
JF - Journal of Biomedical Optics
IS - 8
M1 - 086007
ER -