TY - JOUR
T1 - Multichannel Optically Pumped Atomic Magnetometer With High Resolution and Femtotesla Sensitivity for Biomagnetic Field Measurement
AU - Xu, Xiangjin
AU - Zhai, Yueyang
AU - Zhao, Binbin
AU - Zhang, Yaohua
AU - Yue, Ziqian
AU - Tang, Junjian
N1 - Publisher Copyright:
© 1963-2012 IEEE.
PY - 2025
Y1 - 2025
N2 - In this article, we propose a highly sensitive nine-channel optically pumped magnetometer (OPM), operated in the spin-exchange relaxation-free (SERF) regime, designed to address the challenges of crosstalk arising from magnetic field modulation and low spatial resolution in multichannel OPMs employing individual sensors. By introducing a flat-top beam shaper, the uniformity of atomic polarization within the vapor cell was improved, which enhanced the consistency across all channels. In addition, we analyzed the atomic diffusion crosstalk by varying the beam spacing and measuring the scale factor deviations induced by adjacent channels. Following system optimization, we achieved high-precision magnetic field measurements with a spatial resolution of 3.25 mm and an accuracy quantified by a σi value of 99.73%. Meanwhile, the average bandwidth of the channels was measured at 93 Hz, with the single-channel sensitivity of approximately 11 fT/Hz1/2 and the gradient sensitivity reaching roughly 10 fT/cm/Hz1/2 . Furthermore, an impressive common-mode rejection ratio (CMRR) of 60 dB was realized. The nine-channel OPM was successfully demonstrated by comparing the simulated magnetocardiography (MCG) signals with the corresponding measured signals. With its potentially high spatial resolution and sensitivity, the nine-channel OPM offers a viable alternative to traditional superconducting quantum interference devices (SQUIDs) with compact and wearable advantages for MCG, magnetoencephalography (MEG), and magnetic particle imaging.
AB - In this article, we propose a highly sensitive nine-channel optically pumped magnetometer (OPM), operated in the spin-exchange relaxation-free (SERF) regime, designed to address the challenges of crosstalk arising from magnetic field modulation and low spatial resolution in multichannel OPMs employing individual sensors. By introducing a flat-top beam shaper, the uniformity of atomic polarization within the vapor cell was improved, which enhanced the consistency across all channels. In addition, we analyzed the atomic diffusion crosstalk by varying the beam spacing and measuring the scale factor deviations induced by adjacent channels. Following system optimization, we achieved high-precision magnetic field measurements with a spatial resolution of 3.25 mm and an accuracy quantified by a σi value of 99.73%. Meanwhile, the average bandwidth of the channels was measured at 93 Hz, with the single-channel sensitivity of approximately 11 fT/Hz1/2 and the gradient sensitivity reaching roughly 10 fT/cm/Hz1/2 . Furthermore, an impressive common-mode rejection ratio (CMRR) of 60 dB was realized. The nine-channel OPM was successfully demonstrated by comparing the simulated magnetocardiography (MCG) signals with the corresponding measured signals. With its potentially high spatial resolution and sensitivity, the nine-channel OPM offers a viable alternative to traditional superconducting quantum interference devices (SQUIDs) with compact and wearable advantages for MCG, magnetoencephalography (MEG), and magnetic particle imaging.
KW - Biomagnetic field
KW - flat-top beam
KW - high spatial resolution
KW - multichannel optically pumped magnetometer (OPM)
KW - spin-exchange relaxation-free (SERF)
UR - https://www.scopus.com/pages/publications/105017451075
U2 - 10.1109/TIM.2025.3612562
DO - 10.1109/TIM.2025.3612562
M3 - 文章
AN - SCOPUS:105017451075
SN - 0018-9456
VL - 74
JO - IEEE Transactions on Instrumentation and Measurement
JF - IEEE Transactions on Instrumentation and Measurement
M1 - 1016311
ER -