跳到主要导航 跳到搜索 跳到主要内容

Multi-Level Assessment of Fracture Calluses in Rats Subjected to Low-Magnitude High-Frequency Vibration with Different Rest Periods

  • Jiazi Gao
  • , He Gong*
  • , Xu Huang
  • , Rui Zhang
  • , Renshi Ma
  • , Dong Zhu
  • *此作品的通讯作者
  • Jilin University
  • Beihang University

科研成果: 期刊稿件文章同行评审

摘要

The aim of this study was to investigate the influences of low-magnitude high-frequency vibration (LMHFV) with different rest period regimes (vibrational loading per day [with or without the loading divided into bouts]; or vibrational loading for 7 day followed by 7 day rest [with or without the loading divided into bouts]) on bone healing at multi-levels. Transverse fractures of rat bilateral tibias were established using a Kirschner wire inserted for fixation. The animals were randomly assigned to five groups (n = 7 for each group): four for vibrational groups by LMHFV with different rest period regimes and one for fractured model without mechanical loading. The macromechanical properties of the fractured tibias and the nanomechanical properties of the calluses were investigated through three-point bending and nanoindentation tests, respectively. Atomic force microscopy (AFM) was performed to analyze the nanostructure of the calluses. Micro-computed tomography (micro-CT) scanning was conducted to evaluate the microarchitecture of the calluses. The serum concentration of osteocalcin (OG) and tartrate-resistant acid phosphatase 5b (TRAP5b) were measured to assess the bone formation and resorption rates, respectively. Significantly higher values of failure load and elastic modulus were observed in DL (vibrational loading for 15 min per day) and DLR (vibrational loading per day in which three bouts of 5 min of vibration were separated by 4 h) than FBC (fractured model without mechanical loading) at macro-level (P < 0.05). The results of nanoindentation test showed the highest values of indentation modulus and hardness in DLR (significantly higher than FBC; P < 0.05); besides, higher value of hardness was also observed in DL (significantly higher than FBC; P < 0.05). Though AFM imaging showed no significant differences in grain sizes between the vibrational groups and FBC, roughness of DLR showed the highest value, i.e. it was significantly higher than that in FBC (P < 0.05). For microarchitectural parameters obtained from micro-CT imaging, tissue mineral density (TMD) of DLR and VL7 (vibrational loading for 7 day followed by a 7-day rest, 15 min per day during vibrational periods) were significantly higher than that in FBC (P < 0.05), but no significant differences in other parameters were observed between vibrational groups and FBC. There were no significant differences of OG between vibrational groups and FBC; however, FBC showed significantly higher TRAP5b concentration than all vibrational groups (P < 0.05). The results show that LMHFV with different rest period regimes not only altered the macro- and nano-level bone mechanical properties but also influenced the TMD of calluses and nano-level spatial arrangement (roughness) significantly. The most significant effect of LMHFV with different rest period regimes was observed in DLR, which indicated that both osteogenic accumulation and cellular resensitization can be satisfied under this regimen. Hence, the DLR group demonstrated a great potential in clinical applications.

源语言英语
页(从-至)2489-2504
页数16
期刊Annals of Biomedical Engineering
44
8
DOI
出版状态已出版 - 1 8月 2016
已对外发布

指纹

探究 'Multi-Level Assessment of Fracture Calluses in Rats Subjected to Low-Magnitude High-Frequency Vibration with Different Rest Periods' 的科研主题。它们共同构成独一无二的指纹。

引用此