TY - JOUR
T1 - Monte Carlo simulation-based thinning and calculating method for noninvasive blood glucose sensing by near-infrared spectroscopy
AU - Ma, Congcong
AU - Qin, Jia
AU - Zhang, Qi
AU - Lu, Junsheng
AU - Xu, Kexin
AU - Jiang, Jingying
N1 - Publisher Copyright:
© 2017 The Author(s).
PY - 2017/3/1
Y1 - 2017/3/1
N2 - Previous results show that the floating reference theory (FRT) is an effective tool to reduce the influence of interference factors on noninvasive blood glucose sensing by near-infrared spectroscopy (NIRS). It is the key to measure the floating reference point (FRP) precisely for the application of FRT. Monte Carlo (MC) simulation has been introduced to quantitatively investigate the effects of positioning errors and light source drifts on measuring FRP. In this article, thinning and calculating method (TCM) is proposed to quantify the positioning error. Meanwhile, the normalization process (NP) is developed to significantly reduce the error induced by light source drift. The results according to TCM show that 7μm deviations in positioning can generate about 10.63% relative error in FRP. It is more noticeable that 1% fluctuation in light source intensity may lead to 12.21% relative errors. Gratifyingly, the proposed NP model can effectively reduce the error caused by light source drift. Therefore, the measurement system for FRPs must meet that the positioning error is less than 7μm, and the light source drift is kept within 1%. Furthermore, an improvement for measurement system is proposed in order to take advantage of the NP model.
AB - Previous results show that the floating reference theory (FRT) is an effective tool to reduce the influence of interference factors on noninvasive blood glucose sensing by near-infrared spectroscopy (NIRS). It is the key to measure the floating reference point (FRP) precisely for the application of FRT. Monte Carlo (MC) simulation has been introduced to quantitatively investigate the effects of positioning errors and light source drifts on measuring FRP. In this article, thinning and calculating method (TCM) is proposed to quantify the positioning error. Meanwhile, the normalization process (NP) is developed to significantly reduce the error induced by light source drift. The results according to TCM show that 7μm deviations in positioning can generate about 10.63% relative error in FRP. It is more noticeable that 1% fluctuation in light source intensity may lead to 12.21% relative errors. Gratifyingly, the proposed NP model can effectively reduce the error caused by light source drift. Therefore, the measurement system for FRPs must meet that the positioning error is less than 7μm, and the light source drift is kept within 1%. Furthermore, an improvement for measurement system is proposed in order to take advantage of the NP model.
KW - Monte Carlo simulation
KW - Thinning and calculating method
KW - floating reference theory
KW - light source drift
KW - noninvasive blood glucose sensing
KW - positioning error
UR - https://www.scopus.com/pages/publications/84974851608
U2 - 10.1142/S1793545816500413
DO - 10.1142/S1793545816500413
M3 - 文章
AN - SCOPUS:84974851608
SN - 1793-5458
VL - 10
JO - Journal of Innovative Optical Health Sciences
JF - Journal of Innovative Optical Health Sciences
IS - 2
M1 - 1650041
ER -