TY - JOUR
T1 - Mixing-Space Magnetic Particle Imaging
AU - Zhang, Rui
AU - Sun, Shijie
AU - Sun, Shaoqi
AU - Meribout, Mahmoud
AU - Xu, Lijun
AU - Zhong, Jing
N1 - Publisher Copyright:
© 1963-2012 IEEE.
PY - 2025
Y1 - 2025
N2 - In this article, we propose a novel approach of mixing-space magnetic particle imaging (MPI) based on the combination of the spatial domain and frequency domain. For 2-D MPI, the superparamagnetic iron oxide nanoparticles (SPIONs) spectra are measured for frequency-domain reconstruction in the x-direction, whereas the SPION spectra in different field-free-point (FFP) positions are used for spatial-domain reconstruction in the y-direction. The system matrix is formulated with the SPION spectra in different x positions along the x-direction and different FFP positions along the y-direction, thus allowing to deblur the SPION image in both x- and y-directions. A 2-D MPI system is designed and built to generate a drive field in the x-direction and a shift field in the y-direction, as well as to measure the SPION spectra. Phantom experiments of two spots demonstrate that the proposed approach allows for spatial resolutions of 0.3 mm in the x-direction and 0.8 mm in the y-direction at 1.14 T/m. The SPION samples with different iron concentrations are used to assess the limit of detection (LOD), showing an LOD of 1.04μg (Fe)/mL (104 ng Fe weight) using Perimag SPIONs. The proposed mixing-space MPI approach significantly reduces both the hardware complexity and the processing time for system matrix measurement but still yields good spatial resolution.
AB - In this article, we propose a novel approach of mixing-space magnetic particle imaging (MPI) based on the combination of the spatial domain and frequency domain. For 2-D MPI, the superparamagnetic iron oxide nanoparticles (SPIONs) spectra are measured for frequency-domain reconstruction in the x-direction, whereas the SPION spectra in different field-free-point (FFP) positions are used for spatial-domain reconstruction in the y-direction. The system matrix is formulated with the SPION spectra in different x positions along the x-direction and different FFP positions along the y-direction, thus allowing to deblur the SPION image in both x- and y-directions. A 2-D MPI system is designed and built to generate a drive field in the x-direction and a shift field in the y-direction, as well as to measure the SPION spectra. Phantom experiments of two spots demonstrate that the proposed approach allows for spatial resolutions of 0.3 mm in the x-direction and 0.8 mm in the y-direction at 1.14 T/m. The SPION samples with different iron concentrations are used to assess the limit of detection (LOD), showing an LOD of 1.04μg (Fe)/mL (104 ng Fe weight) using Perimag SPIONs. The proposed mixing-space MPI approach significantly reduces both the hardware complexity and the processing time for system matrix measurement but still yields good spatial resolution.
KW - Limit of detection (LOD)
KW - magnetic particle imaging (MPI)
KW - mixing space
KW - spatial resolution
KW - superparamagnetic iron oxide nanoparticles (SPIONs)
UR - https://www.scopus.com/pages/publications/86000383935
U2 - 10.1109/TIM.2024.3500075
DO - 10.1109/TIM.2024.3500075
M3 - 文章
AN - SCOPUS:86000383935
SN - 0018-9456
VL - 74
JO - IEEE Transactions on Instrumentation and Measurement
JF - IEEE Transactions on Instrumentation and Measurement
M1 - 4500509
ER -