TY - JOUR
T1 - Minority Carrier Lifetime Test With a 3-D Printed Dielectric-Filled Waveguide Probe and Microwave Photoconductivity Decay Technique
AU - Wang, Xueer
AU - Ye, Ming
AU - Zhao, Xiaolong
AU - Yang, Fang
AU - Xiang, Feng
AU - Xie, Yongjun
AU - He, Yongning
N1 - Publisher Copyright:
© 1963-2012 IEEE.
PY - 2025
Y1 - 2025
N2 - With a low-cost fabricated (3-D printed dielectric part and metallization using adhesive copper tape) open-ended rectangular waveguide as a transceiver probe, the groups of microwave photoconductive decay experiments are presented to study the influence of excitation frequency on system performance, such as sensitivity and signal-to-noise ratio (SNR). First, to observe the effect of excitation frequency on the waveguide probe's reflection coefficient, a microwave photoconductivity decay (μ-PCD) setup based on a one-port vector network analyzer is presented. Then, another μ-PCD setup based on conventional architecture is presented for carrier lifetime testing. A standard waveguide probe working at similar frequency band is also used as a benchmark probe. Experimental results show that the proposed 3-D printed waveguide probe offers ≈10 × improved measurement sensitivity compared to the standard waveguide. For the used setup in this work, when excitation power is ≥10 dBm, by properly selecting the excitation frequency, the SNR of μ-PCD system can be improved by at least 10 dB. A detailed analysis of the mechanism of SNR improvement is also presented. The proposed low-cost 3-D printed dielectric-filled waveguide probe provides an alternative for μ-PCD systems.
AB - With a low-cost fabricated (3-D printed dielectric part and metallization using adhesive copper tape) open-ended rectangular waveguide as a transceiver probe, the groups of microwave photoconductive decay experiments are presented to study the influence of excitation frequency on system performance, such as sensitivity and signal-to-noise ratio (SNR). First, to observe the effect of excitation frequency on the waveguide probe's reflection coefficient, a microwave photoconductivity decay (μ-PCD) setup based on a one-port vector network analyzer is presented. Then, another μ-PCD setup based on conventional architecture is presented for carrier lifetime testing. A standard waveguide probe working at similar frequency band is also used as a benchmark probe. Experimental results show that the proposed 3-D printed waveguide probe offers ≈10 × improved measurement sensitivity compared to the standard waveguide. For the used setup in this work, when excitation power is ≥10 dBm, by properly selecting the excitation frequency, the SNR of μ-PCD system can be improved by at least 10 dB. A detailed analysis of the mechanism of SNR improvement is also presented. The proposed low-cost 3-D printed dielectric-filled waveguide probe provides an alternative for μ-PCD systems.
KW - 3-D printing
KW - excitation frequency
KW - microwave photoconductivity decay (μ-PCD)
KW - open-ended rectangular waveguide antenna
KW - signal-to-noise ratio (SNR)
UR - https://www.scopus.com/pages/publications/105001648702
U2 - 10.1109/TIM.2025.3547472
DO - 10.1109/TIM.2025.3547472
M3 - 文章
AN - SCOPUS:105001648702
SN - 0018-9456
VL - 74
JO - IEEE Transactions on Instrumentation and Measurement
JF - IEEE Transactions on Instrumentation and Measurement
M1 - 8002409
ER -