T1 - Microbial fuel cell as power supply for implantable medical devices
T2 - A novel configuration design for simulating colonic environment
AU - Dong, Kun
AU - Jia, Boyang
AU - Yu, Chaoling
AU - Dong, Wenbo
AU - Du, Fangzhou
AU - Liu, Hong
PY - 2013/3/15
Y1 - 2013/3/15
N2 - This study focused on providing power for implantable medical devices (IMDs) using a microbial fuel cell (MFC) implanted in human transverse colon. Considering the condition of colonic environment, a continuous-flow single-chamber MFC without membrane was set up. The performance of the MFC was investigated. The power output of 1.6. mW under the steady state was not rich enough for some high energy-consuming IMDs. Moreover, the parameters of the simulated colonic environment, such as pH and ORP value, varied along with the time. Hence, a new MFC configuration was developed. In this novel model, pH transducers were placed in cathodic and anodic areas, so as to regulate the reactor operation timely via external intervention. And two ORP transducers were inserted next to the pH transducers, for monitoring and adjusting the MFC operation efficiently. Besides, colonic haustra were designed in order to increase the difference between cathodic and anodic areas.
AB - This study focused on providing power for implantable medical devices (IMDs) using a microbial fuel cell (MFC) implanted in human transverse colon. Considering the condition of colonic environment, a continuous-flow single-chamber MFC without membrane was set up. The performance of the MFC was investigated. The power output of 1.6. mW under the steady state was not rich enough for some high energy-consuming IMDs. Moreover, the parameters of the simulated colonic environment, such as pH and ORP value, varied along with the time. Hence, a new MFC configuration was developed. In this novel model, pH transducers were placed in cathodic and anodic areas, so as to regulate the reactor operation timely via external intervention. And two ORP transducers were inserted next to the pH transducers, for monitoring and adjusting the MFC operation efficiently. Besides, colonic haustra were designed in order to increase the difference between cathodic and anodic areas.
KW - Configuration design
KW - Human colon
KW - Implantable medical device
KW - Microbial fuel cell
UR - https://www.scopus.com/pages/publications/84870810404
U2 - 10.1016/j.bios.2012.10.028
DO - 10.1016/j.bios.2012.10.028
M3 - 文章
C2 - 23122754
AN - SCOPUS:84870810404
SN - 0956-5663
VL - 41
SP - 916
EP - 919
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
IS - 1
ER -