TY - JOUR
T1 - Measurement and suppression of tensor light shift for nonlinear magneto-optical rotating atomic magnetometers
AU - Tian, Mengnan
AU - Jiang, Liwei
AU - Chai, Yanchao
AU - Liu, Jiali
AU - Lu, Zhenglong
AU - Chen, Junlin
AU - Zhao, Xin
AU - Quan, Wei
N1 - Publisher Copyright:
© 2025
PY - 2025/8/16
Y1 - 2025/8/16
N2 - In the NMOR atomic magnetometer, the tensor light shift is identified as a critical systemic error that affects the accuracy of magnetic resonance frequency measurements. In this paper, we present a tensor light shift measurement and suppression method based on Linear Resonance Frequency Variation and Reverse Magnetic Compensation (LRFV-RMC), which utilizes the resonance frequency linear dependence on the light shift, along with a suppression technique based on reverse magnetic compensation. To further enhance the compensation accuracy and improve the long-term stability of magnetic field measurement, a closed-loop light power control scheme is introduced. The theoretical models of resonant frequency and tensor light shift are established and the mechanism of the influence of light shift on resonance frequency is clarified. Additionally, the light shift and its corresponding magnetic resonance signals are investigated theoretically and experimentally under different light power, polarization direction and magnetic field amplitude. As a result, compared to the existing system, the proposed method effectively compensates for tensor light shift and improves the long-term stability of the magnetic resonance signal by at least 25.8%. This work provides a practical approach to improving the accuracy and stability of NMOR atomic magnetometers.
AB - In the NMOR atomic magnetometer, the tensor light shift is identified as a critical systemic error that affects the accuracy of magnetic resonance frequency measurements. In this paper, we present a tensor light shift measurement and suppression method based on Linear Resonance Frequency Variation and Reverse Magnetic Compensation (LRFV-RMC), which utilizes the resonance frequency linear dependence on the light shift, along with a suppression technique based on reverse magnetic compensation. To further enhance the compensation accuracy and improve the long-term stability of magnetic field measurement, a closed-loop light power control scheme is introduced. The theoretical models of resonant frequency and tensor light shift are established and the mechanism of the influence of light shift on resonance frequency is clarified. Additionally, the light shift and its corresponding magnetic resonance signals are investigated theoretically and experimentally under different light power, polarization direction and magnetic field amplitude. As a result, compared to the existing system, the proposed method effectively compensates for tensor light shift and improves the long-term stability of the magnetic resonance signal by at least 25.8%. This work provides a practical approach to improving the accuracy and stability of NMOR atomic magnetometers.
KW - Magnetic field compensation
KW - NMOR atomic magnetometer
KW - Resonance frequency
KW - Tensor light shift
UR - https://www.scopus.com/pages/publications/105003215154
U2 - 10.1016/j.sna.2025.116562
DO - 10.1016/j.sna.2025.116562
M3 - 文章
AN - SCOPUS:105003215154
SN - 0924-4247
VL - 390
JO - Sensors and Actuators A: Physical
JF - Sensors and Actuators A: Physical
M1 - 116562
ER -