N2 - Coriolis flowmeters have been proven to be effective while measuring single phase flows, however, the measurement accuracy degrades in case of multiphase flows. In this paper a Gaussian Process Regression (GPR) based soft-computing correction model is proposed for two-phase (sand-water) slurry mass flow measurement using Coriolis flowmeters. Experimental tests were conducted on a purpose-built slurry flow test rig for two different orientations of Coriolis measuring tubes i.e. upward and downward. Five different mass flowrates, 8200, 12000, 14300, 17000 and 20000 kg/h, were tested with Solid Volume Fraction (SVF) ranging between 0 - 1.6%. A number of features, including apparent mass flowrate, density, SVF, and solid weight concentration are used as inputs to GPR models. Two GPR models are trained and tested to estimate the measurement errors of slurry mass flow measurement for the upward and downward orientations of Coriolis flowmeters, respectively. The performances of the GPR models are assessed in comparison with the reference readings. The experimental results suggest that the proposed correction models have successfully limited the relative errors within ±0.2 % for all the five mass flowrates and SVFs from 0-1.6% for both upward and downward orientations of Coriolis flowmeters.
AB - Coriolis flowmeters have been proven to be effective while measuring single phase flows, however, the measurement accuracy degrades in case of multiphase flows. In this paper a Gaussian Process Regression (GPR) based soft-computing correction model is proposed for two-phase (sand-water) slurry mass flow measurement using Coriolis flowmeters. Experimental tests were conducted on a purpose-built slurry flow test rig for two different orientations of Coriolis measuring tubes i.e. upward and downward. Five different mass flowrates, 8200, 12000, 14300, 17000 and 20000 kg/h, were tested with Solid Volume Fraction (SVF) ranging between 0 - 1.6%. A number of features, including apparent mass flowrate, density, SVF, and solid weight concentration are used as inputs to GPR models. Two GPR models are trained and tested to estimate the measurement errors of slurry mass flow measurement for the upward and downward orientations of Coriolis flowmeters, respectively. The performances of the GPR models are assessed in comparison with the reference readings. The experimental results suggest that the proposed correction models have successfully limited the relative errors within ±0.2 % for all the five mass flowrates and SVFs from 0-1.6% for both upward and downward orientations of Coriolis flowmeters.
KW - Coriolis flowmeter
KW - Gaussian process regression
KW - mass flow measurement
KW - slurry flow
KW - solid volume fraction
UR - https://www.scopus.com/pages/publications/85166374916
U2 - 10.1109/I2MTC53148.2023.10175901
DO - 10.1109/I2MTC53148.2023.10175901
M3 - 会议稿件
AN - SCOPUS:85166374916
T3 - Conference Record - IEEE Instrumentation and Measurement Technology Conference
BT - I2MTC 2023 - 2023 IEEE International Instrumentation and Measurement Technology Conference
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2023 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2023
Y2 - 22 May 2023 through 25 May 2023
ER -