TY - JOUR
T1 - Investigation of startup behaviors of a loop heat pipe
AU - Zhang, Hongxing
AU - Lin, Guiping
AU - Ding, Ting
AU - Yao, Wei
AU - Shao, Xingguo
AU - Sudakov, R. G.
AU - Maidanik, Yu F.
PY - 2005
Y1 - 2005
N2 - The results of ground experiments on startup behaviors of a loop heat pipe are presented. One objective is to investigate the effects of working conditions on the startup of loop heat pipes. Startup behaviors as functions of various parameters, including the vapor/liquid distribution in the evaporator, startup heat load, sink temperature, and adverse elevation are described and explained. The physical process of startup is described, and the explanation that pressure transfer leads to the saturated temperature rise in the compensation chamber during startup is discussed. The other objective is to investigate the effect of startup on the steady-state operation of loop heat pipes. Test results indicate that evaporation inside the wick tends to occur at low startup heat loads when the evaporator, including the vapor grooves and the evaporator core, is flooded with liquid. Some peculiar phenomena, including evaporation inside the wick, temperature oscillation at the condenser inlet, and reverse flow equilibrium, which lead to higher operating temperatures, were observed during startup.
AB - The results of ground experiments on startup behaviors of a loop heat pipe are presented. One objective is to investigate the effects of working conditions on the startup of loop heat pipes. Startup behaviors as functions of various parameters, including the vapor/liquid distribution in the evaporator, startup heat load, sink temperature, and adverse elevation are described and explained. The physical process of startup is described, and the explanation that pressure transfer leads to the saturated temperature rise in the compensation chamber during startup is discussed. The other objective is to investigate the effect of startup on the steady-state operation of loop heat pipes. Test results indicate that evaporation inside the wick tends to occur at low startup heat loads when the evaporator, including the vapor grooves and the evaporator core, is flooded with liquid. Some peculiar phenomena, including evaporation inside the wick, temperature oscillation at the condenser inlet, and reverse flow equilibrium, which lead to higher operating temperatures, were observed during startup.
UR - https://www.scopus.com/pages/publications/27844494169
U2 - 10.2514/1.12008
DO - 10.2514/1.12008
M3 - 文章
AN - SCOPUS:27844494169
SN - 0887-8722
VL - 19
SP - 509
EP - 518
JO - Journal of Thermophysics and Heat Transfer
JF - Journal of Thermophysics and Heat Transfer
IS - 4
ER -