TY - JOUR
T1 - Intrinsic background radiation of LaBr3(Ce) detector via coincidence measurements and simulations
AU - Cheng, Hao
AU - Sun, Bao Hua
AU - Zhu, Li Hua
AU - Li, Tian Xiao
AU - Li, Guang Shuai
AU - Li, Cong Bo
AU - Wu, Xiao Guang
AU - Zheng, Yun
N1 - Publisher Copyright:
© 2020, China Science Publishing & Media Ltd. (Science Press), Shanghai Institute of Applied Physics, the Chinese Academy of Sciences, Chinese Nuclear Society and Springer Nature Singapore Pte Ltd.
PY - 2020/10/1
Y1 - 2020/10/1
N2 - The LaBr3(Ce) detector has attracted much attention in recent years because of its superior characteristics compared with other scintillating materials in terms of resolution and efficiency. However, it has a relatively high intrinsic background radiation because of the naturally occurring radioisotopes in lanthanum, actinium, and their daughter nuclei. This limits its applications in low-counting rate experiments. In this study, we identified the radioactive isotopes in the ϕ3 ′ ′× 3 ′ ′ Saint-Gobain B380 detector by a coincidence measurement using a Clover detector in a low-background shielding system. Moreover, we carried out a Geant4 simulation of the experimental spectra to evaluate the activities of the main internal radiation components. The total activity of the background radiation of B380 is determined to be 1.523 (34) Bq/cm3. The main sources include 138La at 1.428 (34) Bq/cm3, 207Tl at 0.0135 (13) Bq/cm3, 211Bi at 0.0136 (15) Bq/cm3, 215Po at 0.0135 (3) Bq/cm3, 219Rn at 0.0125 (12) Bq/cm3, 223Fr at 0.0019 (11) Bq/cm3, 223Ra at 0.0127 (10) Bq/cm3, 227Th at 0.0158 (22) Bq/cm3, and 227Ac at 0.0135 (13) Bq/cm3. Of these, the activities of 207Tl, 211Po, 215Po, 223Fr, and 227Ac are deduced for the first time from the secular equilibrium established in the decay chain of 227Ac.
AB - The LaBr3(Ce) detector has attracted much attention in recent years because of its superior characteristics compared with other scintillating materials in terms of resolution and efficiency. However, it has a relatively high intrinsic background radiation because of the naturally occurring radioisotopes in lanthanum, actinium, and their daughter nuclei. This limits its applications in low-counting rate experiments. In this study, we identified the radioactive isotopes in the ϕ3 ′ ′× 3 ′ ′ Saint-Gobain B380 detector by a coincidence measurement using a Clover detector in a low-background shielding system. Moreover, we carried out a Geant4 simulation of the experimental spectra to evaluate the activities of the main internal radiation components. The total activity of the background radiation of B380 is determined to be 1.523 (34) Bq/cm3. The main sources include 138La at 1.428 (34) Bq/cm3, 207Tl at 0.0135 (13) Bq/cm3, 211Bi at 0.0136 (15) Bq/cm3, 215Po at 0.0135 (3) Bq/cm3, 219Rn at 0.0125 (12) Bq/cm3, 223Fr at 0.0019 (11) Bq/cm3, 223Ra at 0.0127 (10) Bq/cm3, 227Th at 0.0158 (22) Bq/cm3, and 227Ac at 0.0135 (13) Bq/cm3. Of these, the activities of 207Tl, 211Po, 215Po, 223Fr, and 227Ac are deduced for the first time from the secular equilibrium established in the decay chain of 227Ac.
KW - Coincidence measurement technique
KW - GEANT4 simulation
KW - Intrinsic radiation
KW - LaBr
UR - https://www.scopus.com/pages/publications/85092272417
U2 - 10.1007/s41365-020-00812-8
DO - 10.1007/s41365-020-00812-8
M3 - 文章
AN - SCOPUS:85092272417
SN - 1001-8042
VL - 31
JO - Nuclear Science and Techniques
JF - Nuclear Science and Techniques
IS - 10
M1 - 99
ER -