T1 - Influence of the quality of intraoperative fluoroscopic images on the spatial positioning accuracy of a CAOS system
AU - Wang, Junqiang
AU - Wang, Yu
AU - Zhu, Gang
AU - Chen, Xiangqian
AU - Zhao, Xiangrui
AU - Qiao, Huiting
AU - Fan, Yubo
N1 - Publisher Copyright:
Copyright © 2018 John Wiley & Sons, Ltd.
PY - 2018/6
Y1 - 2018/6
N2 - Background: Spatial positioning accuracy is a key issue in a computer-assisted orthopaedic surgery (CAOS) system. Since intraoperative fluoroscopic images are one of the most important input data to the CAOS system, the quality of these images should have a significant influence on the accuracy of the CAOS system. But the regularities and mechanism of the influence of the quality of intraoperative images on the accuracy of a CAOS system have yet to be studied. Methods: Two typical spatial positioning methods – a C-arm calibration-based method and a bi-planar positioning method – are used to study the influence of different image quality parameters, such as resolution, distortion, contrast and signal-to-noise ratio, on positioning accuracy. The error propagation rules of image error in different spatial positioning methods are analyzed by the Monte Carlo method. Results: Correlation analysis showed that resolution and distortion had a significant influence on spatial positioning accuracy. In addition the C-arm calibration-based method was more sensitive to image distortion, while the bi-planar positioning method was more susceptible to image resolution. The image contrast and signal-to-noise ratio have no significant influence on the spatial positioning accuracy. The result of Monte Carlo analysis proved that generally the bi-planar positioning method was more sensitive to image quality than the C-arm calibration-based method. Conclusions: The quality of intraoperative fluoroscopic images is a key issue in the spatial positioning accuracy of a CAOS system. Although the 2 typical positioning methods have very similar mathematical principles, they showed different sensitivities to different image quality parameters. The result of this research may help to create a realistic standard for intraoperative fluoroscopic images for CAOS systems.
AB - Background: Spatial positioning accuracy is a key issue in a computer-assisted orthopaedic surgery (CAOS) system. Since intraoperative fluoroscopic images are one of the most important input data to the CAOS system, the quality of these images should have a significant influence on the accuracy of the CAOS system. But the regularities and mechanism of the influence of the quality of intraoperative images on the accuracy of a CAOS system have yet to be studied. Methods: Two typical spatial positioning methods – a C-arm calibration-based method and a bi-planar positioning method – are used to study the influence of different image quality parameters, such as resolution, distortion, contrast and signal-to-noise ratio, on positioning accuracy. The error propagation rules of image error in different spatial positioning methods are analyzed by the Monte Carlo method. Results: Correlation analysis showed that resolution and distortion had a significant influence on spatial positioning accuracy. In addition the C-arm calibration-based method was more sensitive to image distortion, while the bi-planar positioning method was more susceptible to image resolution. The image contrast and signal-to-noise ratio have no significant influence on the spatial positioning accuracy. The result of Monte Carlo analysis proved that generally the bi-planar positioning method was more sensitive to image quality than the C-arm calibration-based method. Conclusions: The quality of intraoperative fluoroscopic images is a key issue in the spatial positioning accuracy of a CAOS system. Although the 2 typical positioning methods have very similar mathematical principles, they showed different sensitivities to different image quality parameters. The result of this research may help to create a realistic standard for intraoperative fluoroscopic images for CAOS systems.
KW - Monte Carlo analysis
KW - computer-assisted orthopaedic surgery (CAOS)
KW - intraoperative fluoroscopic images
KW - spatial positioning accuracy
UR - https://www.scopus.com/pages/publications/85044601401
U2 - 10.1002/rcs.1898
DO - 10.1002/rcs.1898
M3 - 文章
C2 - 29603587
AN - SCOPUS:85044601401
SN - 1478-596X
VL - 14
JO - International Journal of Medical Robotics and Computer Assisted Surgery
JF - International Journal of Medical Robotics and Computer Assisted Surgery
IS - 3
M1 - e1898
ER -