TY - JOUR
T1 - In Situ Calibration of Coils Constant in a Spin-Exchange Relaxation-Free (SERF) Co-magnetometer
AU - Cao, Qian
AU - Liu, Ying
AU - Tang, Junjian
AU - Zhao, Tian
AU - Heng, Xing
AU - Zhai, Yueyang
N1 - Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2023/6/15
Y1 - 2023/6/15
N2 - We demonstrated an in situ calibration method of magnetic field coils constant in an atomic co-magnetometer based on the pumping effect of the probe laser, which is an effective technique to assist the calibration of coils constant and suppress the inaccuracy arose from the fluctuation of the temperature. With this method, the measured coils constant is 44.10 ±0.71 nT/mA in Y-axis. Moreover, the scale factor K between voltage and internal signal also could be corrected from 0.538 ± 0.009 °/s/V to 0.798 ± 0.016 °/s/V. And the results indicate the higher sensitivity of a SERF co-magnetometer could be achieved with the assisted coils constant. In addition, it can also be used in a no destructive way to decrease the influence of other parts in the device and increase the measured accuracy. Furthermore, it is an achievable method to be applied into a K-Rb-21Ne co-magnetometer whereby the magnetic field shielding condition and SERF regime of alkali-metal atoms will not be destructed.
AB - We demonstrated an in situ calibration method of magnetic field coils constant in an atomic co-magnetometer based on the pumping effect of the probe laser, which is an effective technique to assist the calibration of coils constant and suppress the inaccuracy arose from the fluctuation of the temperature. With this method, the measured coils constant is 44.10 ±0.71 nT/mA in Y-axis. Moreover, the scale factor K between voltage and internal signal also could be corrected from 0.538 ± 0.009 °/s/V to 0.798 ± 0.016 °/s/V. And the results indicate the higher sensitivity of a SERF co-magnetometer could be achieved with the assisted coils constant. In addition, it can also be used in a no destructive way to decrease the influence of other parts in the device and increase the measured accuracy. Furthermore, it is an achievable method to be applied into a K-Rb-21Ne co-magnetometer whereby the magnetic field shielding condition and SERF regime of alkali-metal atoms will not be destructed.
KW - Atomic co-magnetometer
KW - In situ calibration of coils constant
KW - Pumping effect of probe laser
KW - SERF regime
UR - https://www.scopus.com/pages/publications/85151278472
U2 - 10.1016/j.measurement.2023.112812
DO - 10.1016/j.measurement.2023.112812
M3 - 文章
AN - SCOPUS:85151278472
SN - 0263-2241
VL - 214
JO - Measurement: Journal of the International Measurement Confederation
JF - Measurement: Journal of the International Measurement Confederation
M1 - 112812
ER -