TY - JOUR
T1 - Impact of radiative heat flux on turbine blade heat transfer in high temperature environments
AU - Li, Haiwang
AU - Wang, Meng
AU - You, Ruquan
N1 - Publisher Copyright:
© 2022 Elsevier Ltd
PY - 2022/7/25
Y1 - 2022/7/25
N2 - The efficient cooling technology used in first-stage turbine vanes results in a large temperature difference between the blade wall and high-temperature gas. The resulting thermal radiation cannot be neglected. However, in experimental environments, it is impossible to accurately assess the effects of radiation. In this study, a novel, simplified version of an existing experimental method is proposed, to distinguish the radiation from the total heat flux; it uses blade wall-temperature measurements and ternary nonlinear regression. The results show that when the mainstream temperature is 1000–1300 K and the cold air temperature is 550–750 K (T∞/Tcold > 2.5), the radiative heat flux accounts for 15–20% of the total heat flux (when the gas composition is pure air). In real working conditions (T∞/Tcold ≈ 2.2), the radiative heat flux cooled without an air film accounts for 11.96–14.4% of the total heat flux. When the gas includes radiation-participating media (e.g., CO2 and H2O), the radiative heat flux accounts for 21.4–22.72% of the total heat flux. The effects of radiation cannot be neglected in studies considering the heat transfer of turbine blades. In addition, the radiation correction factor is defined to comprehensively account for the effects of radiation. Under real conditions (T∞/Tcold ≈ 2.2), the radiation correction factor is 1.275. Finally, the simplified approach is validated using numerical calculations.
AB - The efficient cooling technology used in first-stage turbine vanes results in a large temperature difference between the blade wall and high-temperature gas. The resulting thermal radiation cannot be neglected. However, in experimental environments, it is impossible to accurately assess the effects of radiation. In this study, a novel, simplified version of an existing experimental method is proposed, to distinguish the radiation from the total heat flux; it uses blade wall-temperature measurements and ternary nonlinear regression. The results show that when the mainstream temperature is 1000–1300 K and the cold air temperature is 550–750 K (T∞/Tcold > 2.5), the radiative heat flux accounts for 15–20% of the total heat flux (when the gas composition is pure air). In real working conditions (T∞/Tcold ≈ 2.2), the radiative heat flux cooled without an air film accounts for 11.96–14.4% of the total heat flux. When the gas includes radiation-participating media (e.g., CO2 and H2O), the radiative heat flux accounts for 21.4–22.72% of the total heat flux. The effects of radiation cannot be neglected in studies considering the heat transfer of turbine blades. In addition, the radiation correction factor is defined to comprehensively account for the effects of radiation. Under real conditions (T∞/Tcold ≈ 2.2), the radiation correction factor is 1.275. Finally, the simplified approach is validated using numerical calculations.
KW - Multi-species
KW - Nonlinear regression
KW - Thermal radiation
KW - Total heat transfer
UR - https://www.scopus.com/pages/publications/85129563507
U2 - 10.1016/j.applthermaleng.2022.118505
DO - 10.1016/j.applthermaleng.2022.118505
M3 - 文章
AN - SCOPUS:85129563507
SN - 1359-4311
VL - 212
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 118505
ER -