摘要
In order to detect remainders in the internal cooling channels by non-destructive means with high accuracy, industrial computed tomography was used to scan the tested blade. The position displacement parameters between the tested blade and the standard specimen were calculated base on the rigid transformation and sinogram projection. Then the sinograms of the scanned slice and the corresponding standard slice were matched together in order to extract the sinogram of the remainders and the reconstructed images of them were obtained.The experimental results prove that this method can extract remainders in the internal cooling channels effectively.Compared to the traditional remainder extraction algorithm based on CT(computed tomography) image, the proposed algorithm is realized in the projection domain, and it is rarely affected by projection data incompleteness, scanning system bias and the reconstruction artifacts, so it has a higher accuracy.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 2433-2438 |
| 页数 | 6 |
| 期刊 | Hangkong Dongli Xuebao/Journal of Aerospace Power |
| 卷 | 26 |
| 期 | 11 |
| 出版状态 | 已出版 - 11月 2011 |
学术指纹
探究 'ICT assisted detection for remainders in the internal cooling channel of the turbine blade' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver