跳到主要导航 跳到搜索 跳到主要内容

High voltage DC leakage detection for double-lined hazardous waste landfill based on finite element method

  • Xiao Ci Zhao*
  • , Yi Du Zhang
  • , Ping Yang
  • , Chang Xin Nai
  • *此作品的通讯作者
  • Beihang University
  • China University of Mining & Technology, Beijing
  • Industrial and Commercial Institute of Shandong

科研成果: 期刊稿件文章同行评审

摘要

According to the structural characteristics of hazardous waste landfill, a new model based on the finite element method (FEM) is developed. The detection layer is considered as a sealed space and it is assumed that total current flows through the leak for the high resistivity of geomembrane liner. The leak current is regarded as a positive point current +I and the other current source is -I. Electrical potential of an arbitrary point in detection layer satisfies Poisson equation. Experiments for detecting leaks in liner were carried out. Excellent agreement between experimental data and simulated model data validates the new model. Parametric curves for a single leak show that with optimum selection of field survey parameters leaks can be detected effectively. For multiple leaks, the simulated results indicate that they are detectable when leak separation is larger than measurement spacing.

源语言英语
页(从-至)585-590
页数6
期刊Journal of Shanghai University
11
6
DOI
出版状态已出版 - 12月 2007

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 12 - 负责任消费和生产
    可持续发展目标 12 负责任消费和生产

学术指纹

探究 'High voltage DC leakage detection for double-lined hazardous waste landfill based on finite element method' 的科研主题。它们共同构成独一无二的学术指纹。

引用此