TY - JOUR
T1 - Hierarchical anatomical structure-aware based thoracic CT images registration
AU - He, Yuanbo
AU - Wang, Aoyu
AU - Li, Shuai
AU - Hao, Aimin
N1 - Publisher Copyright:
© 2022
PY - 2022/9
Y1 - 2022/9
N2 - Accurate thoracic CT image registration remains challenging due to complex joint deformations and different motion patterns in multiple organs/tissues during breathing. To combat this, we devise a hierarchical anatomical structure-aware based registration framework. It affords a coordination scheme necessary for constraining a general free-form deformation (FFD) during thoracic CT registration. The key is to integrate the deformations of different anatomical structures in a divide-and-conquer way. Specifically, a deformation ability-aware dissimilarity metric is proposed for complex joint deformations containing large-scale flexible deformation of the lung region, rigid displacement of the bone region, and small-scale flexible deformation of the rest region. Furthermore, a motion pattern-aware regularization is devised to handle different motion patterns, which contain sliding motion along the lung surface, almost no displacement of the spine and smooth deformation of other regions. Moreover, to accommodate large-scale deformation, a novel hierarchical strategy, wherein different anatomical structures are fused on the same control lattice, registers images from coarse to fine via elaborate Gaussian pyramids. Extensive experiments and comprehensive evaluations have been executed on the 4D-CT DIR and 3D DIR COPD datasets. It confirms that this newly proposed method is locally comparable to state-of-the-art registration methods specializing in local deformations, while guaranteeing overall accuracy. Additionally, in contrast to the current popular learning-based methods that typically require dozens of hours or more pre-training with powerful graphics cards, our method only takes an average of 63 s to register a case with an ordinary graphics card of RTX2080 SUPER, making our method still worth promoting. Our code is available at https://github.com/heluxixue/Structure_Aware_Registration/tree/master.
AB - Accurate thoracic CT image registration remains challenging due to complex joint deformations and different motion patterns in multiple organs/tissues during breathing. To combat this, we devise a hierarchical anatomical structure-aware based registration framework. It affords a coordination scheme necessary for constraining a general free-form deformation (FFD) during thoracic CT registration. The key is to integrate the deformations of different anatomical structures in a divide-and-conquer way. Specifically, a deformation ability-aware dissimilarity metric is proposed for complex joint deformations containing large-scale flexible deformation of the lung region, rigid displacement of the bone region, and small-scale flexible deformation of the rest region. Furthermore, a motion pattern-aware regularization is devised to handle different motion patterns, which contain sliding motion along the lung surface, almost no displacement of the spine and smooth deformation of other regions. Moreover, to accommodate large-scale deformation, a novel hierarchical strategy, wherein different anatomical structures are fused on the same control lattice, registers images from coarse to fine via elaborate Gaussian pyramids. Extensive experiments and comprehensive evaluations have been executed on the 4D-CT DIR and 3D DIR COPD datasets. It confirms that this newly proposed method is locally comparable to state-of-the-art registration methods specializing in local deformations, while guaranteeing overall accuracy. Additionally, in contrast to the current popular learning-based methods that typically require dozens of hours or more pre-training with powerful graphics cards, our method only takes an average of 63 s to register a case with an ordinary graphics card of RTX2080 SUPER, making our method still worth promoting. Our code is available at https://github.com/heluxixue/Structure_Aware_Registration/tree/master.
KW - A novel hierarchical strategy
KW - Anatomical structure-aware strategy
KW - Deformation ability-aware dissimilarity metric
KW - Motion pattern-aware regularization
KW - Thoracic CT registration
UR - https://www.scopus.com/pages/publications/85134272033
U2 - 10.1016/j.compbiomed.2022.105876
DO - 10.1016/j.compbiomed.2022.105876
M3 - 文章
C2 - 35863247
AN - SCOPUS:85134272033
SN - 0010-4825
VL - 148
JO - Computers in Biology and Medicine
JF - Computers in Biology and Medicine
M1 - 105876
ER -