跳到主要导航 跳到搜索 跳到主要内容

Haptic Rendering of Diverse Tool-Tissue Contact Constraints During Dental Implantation Procedures

  • Xiaohan Zhao
  • , Zhuoli Zhu
  • , Yu Cong
  • , Yongtao Zhao
  • , Yuru Zhang
  • , Dangxiao Wang*
  • *此作品的通讯作者
  • Institute Co. Ltd
  • Sichuan University
  • Beihang University
  • Peng Cheng Laboratory

科研成果: 期刊稿件文章同行评审

摘要

Motor skill learning of dental implantation surgery is difficult for novices because it involves fine manipulation of different dental tools to fulfill a strictly pre-defined procedure. Haptics-enabled virtual reality training systems provide a promising tool for surgical skill learning. In this paper, we introduce a haptic rendering algorithm for simulating diverse tool-tissue contact constraints during dental implantation. Motion forms of an implant tool can be summarized as the high degree of freedom (H-DoF) motion and the low degree of freedom (L-DoF) motion. During the H-DoF state, the tool can move freely on bone surface and in free space with 6 DoF. While during the L-DoF state, the motion degrees are restrained due to the constraints imposed by the implant bed. We propose a state switching framework to simplify the simulation workload by rendering the H-DoF motion state and the L-DoF motion state separately, and seamless switch between the two states by defining an implant criteria as the switching judgment. We also propose the virtual constraint method to render the L-DoF motion, which are different from ordinary drilling procedures as the tools should obey different axial constraint forms including sliding, drilling, screwing and perforating. The virtual constraint method shows efficiency and accuracy in adapting to different kinds of constraint forms, and consists of three core steps, including defining the movement axis, projecting the configuration difference, and deriving the movement control ratio. The H-DoF motion on bone surface and in free space is simulated through the previously proposed virtual coupling method. Experimental results illustrated that the proposed method could simulate the 16 different phases of the complete implant procedures of the Straumann® Bone Level(BL) Implants Φ4.8–L12 mm. According to the output force curve, different contact constraints could be rendered with steady and continuous output force during the operation procedures.

源语言英语
文章编号35
期刊Frontiers in Robotics and AI
7
DOI
出版状态已出版 - 20 3月 2020

指纹

探究 'Haptic Rendering of Diverse Tool-Tissue Contact Constraints During Dental Implantation Procedures' 的科研主题。它们共同构成独一无二的指纹。

引用此