TY - GEN
T1 - Geometric parameter identification for spherical actuator calibration based on torque formula
AU - Zhang, Liang
AU - Chen, Weihai
AU - Liu, Jingmeng
AU - Wu, Xingming
PY - 2013
Y1 - 2013
N2 - This paper presents a geometric calibration approach of a permanent magnet (PM) spherical actuator to improve its positioning accuracy. The proposed actuator consists of a ball-shaped rotor with multiple PM poles and a spherical-shell-shaped stator with circumferential air-core coils. Due to manufacturing and assembly restrictions, the actual geometric parameters of the spherical actuator differ from their nominal values. Hence, the identification of such errors is significant for high accuracy motion control. The calibration model is formulated based on the differential form of torque equation. To identify the position vector errors in the magnetization axes of PM poles and coils axes, an iterative least-squares algorithm is employed. The proposed calibration method can also be applied to other PM spherical actuators. To verify the robustness and effectiveness of the proposed calibration algorithm, simulations are conducted on the spherical actuator. The results have shown that the positioning accuracy of the spherical actuator is greatly improved after calibration.
AB - This paper presents a geometric calibration approach of a permanent magnet (PM) spherical actuator to improve its positioning accuracy. The proposed actuator consists of a ball-shaped rotor with multiple PM poles and a spherical-shell-shaped stator with circumferential air-core coils. Due to manufacturing and assembly restrictions, the actual geometric parameters of the spherical actuator differ from their nominal values. Hence, the identification of such errors is significant for high accuracy motion control. The calibration model is formulated based on the differential form of torque equation. To identify the position vector errors in the magnetization axes of PM poles and coils axes, an iterative least-squares algorithm is employed. The proposed calibration method can also be applied to other PM spherical actuators. To verify the robustness and effectiveness of the proposed calibration algorithm, simulations are conducted on the spherical actuator. The results have shown that the positioning accuracy of the spherical actuator is greatly improved after calibration.
UR - https://www.scopus.com/pages/publications/84887307015
U2 - 10.1109/ICRA.2013.6631092
DO - 10.1109/ICRA.2013.6631092
M3 - 会议稿件
AN - SCOPUS:84887307015
SN - 9781467356411
T3 - Proceedings - IEEE International Conference on Robotics and Automation
SP - 3666
EP - 3671
BT - 2013 IEEE International Conference on Robotics and Automation, ICRA 2013
T2 - 2013 IEEE International Conference on Robotics and Automation, ICRA 2013
Y2 - 6 May 2013 through 10 May 2013
ER -